F. DISCHARGE LINES
1. Siphoning
Avoid ending the discharge line lower than the liquid being pumped
unless a siphon breaker is in use. Without a siphon breaker installed,
siphoning may damage the pump.
2. Valves
When using a discharge line throttling valve, it
must
be the same size
as the largest pipe to reduce friction loss. Do
not
install a throttling
value in the suction line.
If using high discharge heads, Weir Specialty Pumps suggests a
throttling valve coupled with a system check valve in the discharge
line. When the pump is stopped, this helps ensure the pump is safe
from reverse rotation and extreme shock pressure.