WSP™
DATA SHEET
WSP™ SELF-PRIMER PUMPS
WSP-D300_10
Rev. 3
01/09/20
© 2019 The Factory
35
Install the 2 check valve retaining block pads when the check valve retaining blocks
are positioned in the appropriate place.
Check the check valve cover plate gasket thoroughly and install a new one if it is
worn or damaged. Then use the attaching hardware to install the check valve cover
plate and gasket.
NOTE:
If you removed the suction or discharge flanges, replace both gaskets and
attach them to the pump casing with their attaching hardware.
N. IMPELLER & FRONT WEARPLATE CLEARANCE ADJUSTMENT
After the suction inlet is installed, ensure the rotating assembly retaining plate’s outer
bolt circle is loose, and be sure the inner bolt circle is tight. Tighten the outer bolt
circle evenly on the rotating assembly while revolving the pump shaft until the
impeller scrubs the wearplate. This will indicate when the impeller is in contact with
the front wearplate. Measure the distance between the rotating assembly retaining
ring and the pump case.
Take out 3 bolts to loosen the outer bolt circle of the rotating assembly retaining ring,
and reattach them in the retaining ring’s 3 jack bolt holes. Evenly tighten the 3 jack
bolts to force the rotating assembly out of the pump case and allow installation of
shims measuring from .010 to .015 more than the previous clearance. Take out the
3 jack bolts and return them o their prior position with an adequate amount of shims.
Repeat this procedure on the remaining outer bolt circle bolts.
You may need to repeat the adjustment procedure from time to time to make up for
normal sear between the impeller and the wearplate.
V. MAINTAINING THE PRESSURE RELIEF VALVE
A pressure relief valve is provided for additional safety to the pump and its operator.
It is located on the pump casing (Refer to Liquid Temperature & Overheating in
Section IX. OPERATION, Part C. 4 of the instructions).
WSP™ recommends replacing the pressure relief valve assembly during every
scheduled major maintenance operation or any time the pump overheats, causing
the valve to activate.
Never
replace the pressure relief valve with a non-approved
substitute. It
must be
an approved replacement unit from Weir Specialty Pumps.
Remove, inspect and clean the pressure relief valve regularly. When the inspection
and cleaning are completed. apply
Loctite Pipe Sealant with Teflon No. 592
or an
equivalent product on the relief valve threads before reinstalling in the pump.
A. Final Pump Assembly
Install the shaft key and any protective guards used over the rotating parts
before reconnecting the pump to its power source.
Содержание 10-WSP
Страница 64: ...WSP DATA SHEET WSP SELF PRIMER PUMPS WSP D300_10 Rev 3 01 09 20 2019 The Factory 64 ...
Страница 66: ...WSP DATA SHEET WSP SELF PRIMER PUMPS WSP D300_10 Rev 3 01 09 20 2019 The Factory 66 ...
Страница 67: ...WSP DATA SHEET WSP SELF PRIMER PUMPS WSP D300_10 Rev 3 01 09 20 2019 The Factory 67 ...
Страница 68: ...WSP DATA SHEET WSP SELF PRIMER PUMPS WSP D300_10 Rev 3 01 09 20 2019 The Factory 68 ...
Страница 69: ...WSP DATA SHEET WSP SELF PRIMER PUMPS WSP D300_10 Rev 3 01 09 20 2019 The Factory 69 ...
Страница 70: ...WSP DATA SHEET WSP SELF PRIMER PUMPS WSP D300_10 Rev 3 01 09 20 2019 The Factory 70 ...