Control panel SP231
Configuration of control panel operation
©1997-2015 Trikdis
41
www.trikdis.com
6.13.2
PGM output remote control
When any of PGMx output is set for operating in Remote Control mode, the status of such output will be available
for remote control - by SMS message or phone call. This function is used when it is needed to turn on/off home
automatics by remote control (gate lifting motor, irrigation pump, heater, cooler, etc.) without changing
premises protection mode.
Remote control mode is selected in Control Mode field:
Level - a status will change and remain the same until the next command.
Pulse - a status will take time as indicated in Pulse Time field.
For control by SMS message, see 7 “Programming and control by SMS messages”.
For control by call, see 6.14 Control by call.
6.14
Control by call
Control-by-call function is designed for remote control of partition statuses and PGM remote control mode
outputs. One call can control:
one partition selected;
one PGM output selected;
selected partition together with PGM output.
Control by call is available only from phone numbers attributed to the users, see 6.9 User access parameters.
6.14.1
Partition control
By means of call the existing partition mode can be disabled and switched into DISARM, and when DISARM is
on, ARM mode is activated.
Call control for partition is enabled in partition settings, see 6.8 “Partition parameters”. A partition desired to
be controlled, first of all, must be enabled for operation remotely by checking Remote box. The next step is to
check Dial box to select one of possible partitions.
6.14.2
PGM Output control
By means of call the output set by Pulse mode can be activated or Level mode status inverted.
To enable call control, check Dial in PGM output settings, see 6.13 “PGM output configuration”.
Note. When partition remote control is enabled, Keyswitch zone operation mode is rewritten into pulse mode.