Control panel SP231
Configuration of control panel operation
©1997-2015 Trikdis
30
www.trikdis.com
Zone report parameters
Name
Description
Zn
Zone sequence number
CID code
Zone Contact ID event code (will be set automatically when the zone function is selected).
Report Enable
When it is checked, the event report sending will be on.
Zone Name
Zone name is entered which will be visible in SMS text.
6.7.3
Zone function description
Zone
function
The control panel operation after the zone event
Keyswitch
By changing the status of this input it is possible to turn on/off the alarm system. The alarm
system is on when Exit Delay is set. This time interval is designated for unhindered leave of the
protected premises via the exit route. Respective report is sent after the zone status changed.
Delay
When the alarm system is on, the input zone Delay violation is allowed within the Exit Delay
time.
If after such time expired the zone remains violated, Bell and Flash output signals are being
generated and reports sent.
If the zone is violated when the alarm system is on, Entry Delay time counting is started. Within
this time the alarm system must be turned off, otherwise Bell and Flash output signals will be
generated and reports sent.
Interior
If the zone is violated when the alarm system is on, Bell and Flash output signals will be
immediately generated and reports sent. Zone violation is allowed within the time of Entry
Delay and Exit Delay.
Interior
STAY
Operates in the same way as Interior, however, when security mode STAY or SLEEP is on, the
control panel will not respond to the zone violations.
Instant
If the zone is violated when the alarm system is on, Bell and Flash output signals will be
immediately generated and reports sent.
Instant
STAY
Operates in the same way as Instant, however, when security mode STAY or SLEEP is on, the
control panel will not respond to the zone violations.
24 hours
If the zone is violated at any time, Bell and Flash output signals will be immediately generated
and reports sent.
Fire
If the zone is violated at any time, Bell and Flash output signals will be immediately generated
and reports sent.
Silent
If the zone is violated at any time, the reports are sent immediately, however Bell and Flash
output signals will not be generated
.
6.8
Partition parameters
Partition is a group of independently protected zones. The alarm system can be divided into separately
protected parts. The partitions are configured in the program menu System Options > Partitions.
Partitions are enabled and added in Partitions Enabled field. Maximum number of partitions - 8. Partitions are
added and disabled in the sequence order. In order to disable a partition, it is necessary such partition to be no
longer used. Trying to disable a partition which is still being used, a report, indicating where to refuse such
partition usage, will pop-up.
Double-click with mouse left button on the selected partition line to open such partition settings window.
Partition settings can be changed also by directly changing settings in the partition line.