Control panel SP231
Configuration of control panel operation
©1997-2015 Trikdis
31
www.trikdis.com
Partition parameters
Name
Description
ID
Partition sequence number
Partition Name
Partition name. Default settings provide partition names such as Area 1, Area 2, Area 3 and
etc. The name can be changed by clicking on the notation.
Entry
Entry time given to the partition, when entering via Delay set zone Time shall be written in
seconds, duration from 0 to 255.
Exit
Exit time given to the partition, when entering via Delay set zone Time shall be written in
seconds, duration from 0 to 255.
Bell
Duration of audible signal (sirens, Bell) after the alarm system activated. Time shall be written
in seconds, duration from 0 to 9999.
Squawk
Partition Bell Squawk function is on. One short siren (output Bell) signal will be generated
during the alarm system on, and two short signals - during alarm system off.
Re-ARM
Partition arming (Re-ARM function) against accidental alarm system deactivation is enabled.
When the alarm system is enabled remotely but not violating the entry zone after entry delay
time, the alarm system will turn on in its previous arming mode.
Keyswitch
Keyswitch zone entry control type is indicated and also system control is operated; the only
Pulse mode is possible in order to have a remote control for the system.
Remote
Partition, remote control option (Registered numbers control by SMS message and calls) is
enabled.
Dial
Partition, status control by call is enabled.
P1-P8
Jointly operated partitions are indicated by checking the boxes (the partition automatically
turns into the arming status when all the checked partitions are in the arming status).
Partition parameters