Control panel SP231
Configuration of control panel operation
©1997-2015 Trikdis
26
www.trikdis.com
6.5.5.2
Emergency help button modes
The keyboard can send emergency calls Panic, Medical, Fire.
Their operation modes are to be set in System Options > System general > Keyboard Settings field, by
selecting the respective mode:
Silent
–
silent mode without activation of siren and light alarm.
Audible
–
audible mode when keyboard and bell sirens, and light indicator are activated.
6.5.5.3
Display of the system state
Keypad can constantly display the state of the partitions. Constant status display can be disabled and to
temporary view a partition state a user code must be entered. To enable this function, go to System Options >
System general > Keyboard Settings and select Enter code to view system state. If security Grade 3 is set the
function is enabled automatically.
6.6
System troubles
For the control panel to display trouble in the keyboard or to send a trouble report after troubleshooting, can
be set in the program menu System Options > System Troubles. Also an option to turn on the mode ARM in
case of trouble.
Trouble parameters, first part
Name
Description
ID
Trouble identification number
Trouble
Trouble name
Enable
When it is checked the trouble indication and trouble report sending will be on.
Restrict ARM
When it is checked, in case of such trouble, the arming activation will be restricted.
Trouble descriptions
Trouble name
Description
AC Trouble
Missing main power source.
Battery Trouble
Back-up battery is missing or below its voltage limit.
Aux Trouble
Exceeded current limit or short-circuited AUX output.
Bell Trouble
Missing siren.
Trouble parameters, first part