Operation after tamper event
Name
Description
Tamper Disable
Response to tamper events is disabled.
Trouble when disarmed /
alarm when armed
When disarmed, the tamper event will mean system trouble, and when armed,
the tamper event will mean alarm.
Trouble always
Response to as problem is always on.
Audible alarm when
disarmed / alarm when
armed
When disarmed, the tamper event will be accompanied by siren sound, and
when armed, the tamper event will mean alarm.
6.6.2
Control panel watch-dog
Control panel continuously monitors its functioning and whenever its work gets disrupted it resets and returns
to its previous state. After system reset the System reset event is generated.
6.7
Zone parameters
6.7.1
Main zone parameters
Each ZNx input may be described as a separate zone. To set separate zone parameters go to the program menu
Zones > Zones settings.
Convenient! Double-click with mouse left button on the selected zone line to open such zone settings window.
Zone parameters
Name
Description
Zn
Zone sequence number
Input
Zone physical address. Information displayed: <module identification number>, <module
name>, < ZNx input number>.
P
Zone belonging to partition. Each zone can be attributed to the preferred partition.
Bypass
When it is checked, the option to activate the zone Bypass function during operation will be on.
The function allows disabling, for instance, the zone affected by trouble, in order the system
can be armed despite of such fault.
Tamper
Tamper tracking function will be on when it is checked. When the sensor circuit of type
"normally closed circuit with end of line resistor and tamper tracking" is connected to the ZN
contact and having the event occurred, the system will recognize whether it is the alarm event
or tamper event. If such event is recognized as tamper event, the system will start operating
under the operation type set in System fault > Tamper Recognition (see 6.6.1
"
Tamper
recognition
"
).
Shutdown
When it is checked, the function of short-term zone shutdown will be on. During the armed
mode, when the particular number of zone events set in Alarm has occurred, the other events
Zone parameters