Control panel SP231
Configuration of control panel operation
©1997-2015 Trikdis
44
www.trikdis.com
6.17
Wireless sensors registration
Control panel SP231 can communicate and control UAB Trikdis distributed wireless devices via wireless RF
receiver RF-MOD. Below you can find how to register wireless devices to control panel SP231 using TrikdisConfig
software.
IMPORTANT:
To use wireless sensors, first tick checkbox next to Wireless enabled in window System Options -> System
general tab.
And press Write [F5]!
Go to Wireless sensors window, press Scan button to detect already registered devices in tabs Detector,
Sirens, Pendants. Depending on device category go to tab and register (learn) it.
In all tabs, wireless receiver RF-MOD will appear after button Update status will be pressed.
Receiver parameters
Name
Description
RF receiver status
When receiver is connected, status will change to ONLINE
Software version
Receiver`s software version
Hardware version
Receiver`s hardware version
6.17.1
Detectors
In this tab these detectors will be shown: PET Immune PIR Detector, Magnetic Contact, Smoke & Heat
Detector, Glass Break Detector, Curtain Motion Detector, Flood Sensor.
Learning:
1)
To start “Learn” procedure, press the button Start learning.
2)
Insert battery to the sensor; wait until red/green LED will stop blinking.
3)
For few seconds (1-2s) press tamper switch on detector`s circuit board.
4)
Detector`s LED will start flashing red/green.
Note: How to physically connect RF-MOD to SP231 go to 5.9 Connection of wireless sensors.
Enable Wireless
Receiver parameters