of the same zone will not be responded for the time set in Repeat. After this time expired (or
when disarmed), a new count of the number of zone events will be started.
Force
When it is checked, the activation of Force Arm mode will be available. i.e. the arming will be
allowed when the zone is violated. If the violated zone after the arming enabled, resets to its
normal status, then, in case of later zone event it will be responded.
Mask.
Anti-mask tracking function will be on when it is checked. When the sensor circuit of type "
Normally closed circuit with tamper anti-masking recognition " is connected to the ZN contact
and having the event occurred, the system will recognize whether it is the alarm or tamper or
anti-masking event.
Definition
One of 9 potential zone functions can be set. How the system restarts operating after the zone
event (sensor response and reset signal displaying) depends on the set zone function. For zone
functions see 6.7.3
„
Zone function description
“
.
Type
Set which type of sensor circuit connected to ZNx input should be tracked. Options available:
NC
–
Normally Closed, NO
–
Normally Open, EOL
–
End Of Line.
Delay
Setting of zone sensitivity The zone events shorter than ones set in the box will not be
responded.
Repeat
Insensitive time to recurrent zone events For more details see Shutdown.
Alarm
The maximum allowable number of recurrent zone events. For more details on operation see
Shutdown.
6.7.1.1
Door Chime function.
At OFF/DISARM mode, the control panel can for a short while activate PGM output with the set Buzzer function
and keyboard audible signal - buzzer and thereby to warn that Delay zone is being violated, i.e. door
opening/closing. For activation of Door Chime function, Door chime box must be checked in System Options >
System general > System options.
6.7.1.2
Setting of Fire zones
Any ZNx input of the control panel can be set as Fire zone and a four-wire smoke detector can be connected
thereto.
In order to connect a two-wire smoke detector it should be connected to ZN8 input, which must be set:
a)
as Fire zone,
b)
input target for two-wire smoke detectors must be on (Set zn8 as 2wire box must be checked in System
Options > System general > System option).
When needed, a two-wire smoke detector connected to ZN8 can be reset by means of the keyboard or SMS
message.
6.7.2
Parameters of zone event reports
In the program menu Zones > Zones reporting are to be indicated the zone sequence numbers, the event Contact
ID protocol codes, alarm report sending on/off and SMS message text entered.
Zone report parameters