Control panel SP231
Configuration of control panel operation
©1997-2015 Trikdis
25
www.trikdis.com
6.5.3
Setting of control panel clock
The control panel sends reports with timestamps. To set the control panel clock go to System Options >
System general > Timers.
The control panel clock can be set automatically and stay synchronised or can be set manually.
o
To set the clock automatically, at Time synchronization choose a source (Primary channel,
Protegus server) to which time will be set.
o
To set the clock manually, click Set time from PC button and the clock will be set using
computer’s clock.
To view control panel time, click Read module time. After the click the program will display current
control panel time above the button.
6.5.4
Regular connectivity checks
Control panel can regularly report its status. If Grade 2 or Grade 3 security level is used, connectivity check reports
must be configured. Based on the time set control panel will send reports to:
User, if User Reporting is on and Test/Misc is checked (see 6.12 Report transmission to user)
Centralised Monitoring System, if CMS Reporting is on (see 6.11 Report transmission to CMS )
For reports to be sent to the user, Enable must be checked at Event Summary > 37 Periodical Test 602. Periodical
test report also includes additional information about GSM signal strength, control panel power supply and
battery statuses. This information is sent to the Central Monitoring System separately. For CMS to receive it,
Event Summary > 41 GSM Level 660 must be checked. This setting is on by default in factory settings.
Connectivity checks can be done in two ways: with day-based or minute-based reference time. Settings for
connectivity checks can be adjusted in System Options > System general > Timers.
Day-based reference reports can be sent at the defined time at the specified interval in days. Choose
Days under the Test period and enter the number of days between check reports sent. Enter report
sending time in the Test time field.
Minute-based reference reports can be sent at the specified interval in minutes. Choose Minutes under
the Test period and enter the period specifying the frequency of sending the reports. Reference time
counting will begin with control panel restart and occur for the first time once the settings are entered
in the control panel by clicking the Write button.
Connectivity checks are off if Test disable is selected under the Test period.
6.5.5
Keyboard parameters
6.5.5.1
Keyboard lockout
Keyboard lockout function is activated after the respective number of unsuccessful attempts to enter the control
codes, and it shall be blocked for the selected period of time, when the period passes keyboard will be locked
after every unsuccessful attempt. After keyboard lockout, the report Access denied is being generated and sent.
At Grade 2 or Grade 3 security, the number of allowable incorrect attempts is from 3 to 10.
Keyboard lockout is to be set in System Options > System general > Keyboard Settings:
Set the number of attempts in Keypad lockout counter field.
Set the lockout time (in minutes) in Keypad lockout duration field.
Note. Under security Grade 2 the maximum length of test period – 1 day, under security Grade 3 the maximum
length – 1 minute.