
Telephone Button Programming
300 Series Programs
Strata CTX Programming - Part 3:Telephone Button Programming 04/03
13-61
T
e
lep
hone
Button
Pr
o
g
ram
m
ing
310-04
MOH Source
)%
, n,
+ROG
,
+ROG
n =
1.
Silence
2.
External 1 (default)
3.
External 2
4.
External 3
5.
External 4
6.
External 5
7.
External 6
8.
External 7
9.
External 8
10. External 9
11. External 10
12. External 11
13. External 12
14. External 13
15. External 14
16. External 15
Select the MOH source for Analog DIT Trunk. The Scroll key must be
used to select MOH sources indicated by 10 or higher.
311
DISA Security Codes
,
+ROG
This command assigns DISA parameters.
311-01
DISA Enabled
)%
, n,
+ROG
n =
1.
Enable
2.
Disable (default)
Enable DISA security code.
311-02
DISA Code
)%
, n,
+ROG
n =
Up to 15 digits
Enter DISA security code.
311-03
Response Timer
)%
, n,
+ROG
n =
0~30
(default = 5)
Enter the time, in seconds, for Strata CTX to respond to a call.
311-04
Idle Timer
)%
, n,
+ROG+ROG
n =
0~60
(default = 10)
Enter the time in seconds to wait for idle DTMF.
313
Caller ID Assignment
,
+ROG
This program assigns Caller ID circuits to the CO Line to which the
circuit is connected. The ANI, DNIS, DID formats for TI and analog
DID CO Lines are also defined.
313-00
Trunk Number
n,
+ROG
,
n =
1~64 (CTX100)
1~96 (CTX670 Basic)
1~264 (CTX670 Exp.)
Enter the Trunk Number.
313-01
Signalling Method
)%
, n,
+ROG
n =
1.
None (default)
2.
ANI/DNIS-MCI
3.
ANI/DNIS-Sprint
4.
CLASS (Caller ID)
Specify the format for the interface being used.
313-02
Signalling Contents
)%
, n,
+ROG
n =
1.
ANI and DNIS (default)
2.
ANI only
3.
DNIS only
4.
DID only
Specify the contents of the ANI/DNIS format.
313-03
CLASS Equipment
Position
)%
, xxyyzz,
+ROG
xx =
Cabinet 01 (CTX100),
01~02 (CTX670 Basic),
01~07 (CTX670 Exp.)
If the CLASS type is chosen, the trunk must be assigned to a Caller
ID circuit. Enter the RCIU/RCIS equipment number as xxyyzz.
Notes
•
CLASS equipment numbers are required when assigning a trunk
to a RCIU/RCIS circuit.
•
It can also be used to display the equipment location of existing
caller ID circuit to trunk assignments. Example: If the trunk should
be connected to a caller ID circuit (RCIU/RCIS) in cabinet shelf 5,
slot 2, circuit 3, enter 050203.
yy =
Slot 01~8 (CTX100),
01~10 (CTX670)
zz =
Circuit 01~08
Programs 303~315
(continued)
Button
Sequence
Value(s)
Summary
Содержание Strata CTX
Страница 14: ...Contents Appendix E Software and Firmware Updates x Strata CTX Programming 04 03 ...
Страница 19: ...726 Telecommunication Systems Division April 2003 Part 1 Getting Started Digital Business Telephone Systems ...
Страница 20: ......
Страница 36: ......
Страница 60: ...Installation Step 6 Exit CTX WinAdmin 3 18 Strata CTX Programming Part 2 CTX WinAdmin Programming 04 03 ...
Страница 172: ...Trunks Trunk DID DNIS Setup Wizard 6 40 Strata CTX Programming Part 2 CTX WinAdmin Programming 04 03 ...
Страница 176: ...Attendant 400 Emergency Call Destination Assignment 7 4 Strata CTX Programming Part 2 CTX WinAdmin Programming 04 03 ...
Страница 278: ......
Страница 395: ...726 Telecommunication Systems Division April 2003 Part 4 Appendices Digital Business Telephone Systems ...
Страница 396: ......
Страница 460: ...Strata CTX DK Program Cross reference Strata CTX to Strata DK C 28 Strata CTX Programming Part 4 Appendices 04 03 ...
Страница 516: ...Record Sheets Services D 56 Strata CTX Programming Part 4 Appendices 04 03 ...