Trunks
300 Trunk Assignment
Strata CTX Programming - Part 2: CTX WinAdmin Programming 04/03
6-7
T
runk
s
01 Line Equipment No.
Enter the line equipment number as xxyyzz. Equipment numbers are required
when assigning a new trunk to the system. It can also be used to display the
equipment location of existing trunks.
Example: If the trunk should be connected to an RCOU in cabinet shelf 5, slot
2, circuit 3, enter 050203.
Possible values: xx = Cabinet 01~07; yy = Slot 01~10; zz = Circuit 01~08
...or zz = T1 Circuit 01~24 (CTX670).
xx = Cabinet 01; yy = Slot 01~8; zz = Circuit 01~08
(CTX100) (default = no value).
Cabinet numbers:
•
CTX100 – Select 01 for Base and Expansion cabinet.
•
CTX670 – Select 01 for Base and 02~07 respectively for each Expansion
cabinet.
Slot numbers:
•
CTX100 – Select 01~04 for Base slots and 05~08 for Expansion slots.
•
CTX670 – Select 01~08 for Base slots and 01~10 for Expansion slots.
02 Incoming Line Group
Assign the trunk to Incoming Line Group. Two-way trunks need to be members
of one incoming and one outgoing line group.
Possible values: 0~32 (CTX100), 0~50 (CTX670 Basic), 0~128 (CTX670
Exp),
(default = 0)
03 Outgoing Line Group
Assign the trunk to Outgoing Line Group. Two-way trunks need to be members
of one incoming and one outgoing line group.
Possible values: 0~32 (CTX100), 0~50 (CTX670 Basic), 0~128 (CTX670
Exp),
(default = 0)
04 Dial Mode
Enter the Dial Mode.
Possible values: DP 10PPS, DP 20PPS or DTMF (default)
•
DP 10 PPS = Rotary Dial, 10 PPS
•
DP 20 PPS = Rotary Dial, 20 PPS
05 Signaling
Enter the signalling type.
Possible values: DID, Loop (default), Ground, Tie, LP (Japan), SR (Japan) or
ACU (UK)
06 Start Method
Enter the Start Method. This setting defines the start protocol method used
between the PSTN and this trunk. For DID/Tie trunks.
Possible values: Immediate Start (default), Timing Start or Wink Start
07 Release Supervision
Enable Release Supervision from the CO.
Possible values: Received or Not Received (default)
08 Answer Supervision
Enable Answer Supervision from the CO.
Possible values: Received or Not Received (default)
09 Trunk Name
Enter the trunk name.
Possible values: Up to 14 ASCII characters (default = no value)
F
IELD
D
ESCRIPTION
Содержание Strata CTX
Страница 14: ...Contents Appendix E Software and Firmware Updates x Strata CTX Programming 04 03 ...
Страница 19: ...726 Telecommunication Systems Division April 2003 Part 1 Getting Started Digital Business Telephone Systems ...
Страница 20: ......
Страница 36: ......
Страница 60: ...Installation Step 6 Exit CTX WinAdmin 3 18 Strata CTX Programming Part 2 CTX WinAdmin Programming 04 03 ...
Страница 172: ...Trunks Trunk DID DNIS Setup Wizard 6 40 Strata CTX Programming Part 2 CTX WinAdmin Programming 04 03 ...
Страница 176: ...Attendant 400 Emergency Call Destination Assignment 7 4 Strata CTX Programming Part 2 CTX WinAdmin Programming 04 03 ...
Страница 278: ......
Страница 395: ...726 Telecommunication Systems Division April 2003 Part 4 Appendices Digital Business Telephone Systems ...
Страница 396: ......
Страница 460: ...Strata CTX DK Program Cross reference Strata CTX to Strata DK C 28 Strata CTX Programming Part 4 Appendices 04 03 ...
Страница 516: ...Record Sheets Services D 56 Strata CTX Programming Part 4 Appendices 04 03 ...