Getting Started
Isolating EPS-R cage and cooling fan unit failures
36
Intake fan
- The server has two intake fan bays. If one module is installed and the intake
fan on that module fails, the server can overheat, resulting in lost or corrupted data and/
or programs. In this case, shut down the server immediately and replace the failed fan. If
two modules are installed and one module fails, the server will continue running in a
“downgraded operational state”. Depending on the temperature and installation
conditions, prolonged downgraded operation could shorten the service life of each
system component. If both intake fans fail, shut down the server immediately and replace
the failed fans.
HDD status indicators
The Toshiba Magnia 3310/3310R server can accommodate up to 6 hard disk drives. The
status of each hard disk drive is indicated by both a DC power indicator and a status
indicator under each drive bay.
When the status indicator is amber, and your system has a built-in RAID controller the
corresponding hard disk drive may be faulty. If the drive is defective, replace it. For more
information on changing hard disk drives, see
Replacing a hard disk drive
on page 95.
Lamp
Status
Meaning
DC
power
Off
No hard disk drive is installed.
No power is supplied to the hard disk drive.
Green
Power is supplied to the hard disk drive.
Status
Off
No data is being read or written.
Green
Data is being read or written.
Amber
Failure condition has occurred (valid only when the RAID
controller is in use).
Flashing
amber
The disk array is being rebuilt (valid only when the RAID controller
is in use).