![Toshiba Magnia 3310 Скачать руководство пользователя страница 103](http://html.mh-extra.com/html/toshiba/magnia-3310/magnia-3310_user-manual_430108103.webp)
Connecting Hardware Devices
Power supply units
103
Power supply units
The Toshiba Magnia 3310/3310R server can be configured with an optional second
power supply configuration for load sharing and fault protection.
EPS-R power supply units
The Toshiba Magnia 3310 server supports a redundant power supply configuration,
which allows the server to continue operating if one of the EPS-R power supply units
fails. If a power supply fails, the indicator on the faulty power unit goes out and the fault
lamp located on the front of the server (
) blinks. The server reconfigures itself to
support a single power supply configuration, allowing you to replace (hot swap) the faulty
power supply without shutting down the system. Once you have replaced the faulty
power supply, the server returns to its original redundant power configuration.
Magnia 3310 with redundant EPS-R module
Expansion slots
Security loop
Power supply slot
Standard EPS-R module
Redundant EPS-R module
Содержание Magnia 3310