![Toro 34215 Скачать руководство пользователя страница 24](http://html1.mh-extra.com/html/toro/34215/34215_operators-manual_1133878024.webp)
g027328
Figure 21
Pan spacing for larger granule materials
1.
Spreader moving toward
pans
4.
L1 and R1 collection pan
gap (spread apart to allow
machine to pass through)
2.
Center pan
5.
30 cm (12 inch) gap
3.
Collection pans (gap
between each)
6.
Graduated measuring
cylinder
•
For small granule materials:
Place 6 additional pans, on each side, with
no gap in between each pan (
g027327
Figure 22
Pan spacing for small granule materials
1.
Spreader moving toward
pans
4.
Right collection pans (no
gap between each)
2.
Center collection pan
5.
L1 and R1 collection pan
gap (spread apart to allow
machine to pass through)
3.
Lest collection pans (no
gap between each)
6.
Graduated measuring
cylinder
3.
Move the machine far enough away from the
test area (where the collection pans are located)
to ensure that the machine travels at the desired
spreading speed before reaching the site.
4.
Determine the application rate and the related
drop-rate cam setting; refer to
(page 29)
.
5.
Rotate the drop rate cam (
) to the cam
setting you determined in step
.
g259776
Figure 23
1.
Drop rate cam
6.
Fill the hopper approximately half-full with the
desired material; refer to
.
Determining the Distribution Pattern
1.
Set the spreader pattern control to the middle of
its travel; refer to .
2.
Set the impeller speed to the appropriate
broadcasting rate.
3.
Drive the machine toward the test site at the
appropriate speed.
4.
As you approach the center pan, pull the wide
distribution granular gate control to the open
position, and drive over the center pan.
5.
Close the gate control, move motion-control
lever to the N
EUTRAL
position, shut off the
engine, wait for all moving parts to stop, remove
key, and engage parking brake.
6.
Label each graduated measuring cylinder to
correspond with the distribution pans (such as
L2, L1, Center, R1, R2); refer to
and
7.
One at a time, take a collection pan and dump
the contents into the corresponding graduated
cylinder. Record the amount of material
collected and return the pan to its location.
Repeat this until all pan contents have been
emptied.
Note:
Repeat broadcasting over the test site
several times, moving in the same direction
each time, until enough material is dispensed to
the collection pan to half fill a graduated cylinder.
24
Содержание 34215
Страница 75: ...Schematics g027149 Electrical Schematic Rev A 75...
Страница 76: ...g027148 Electrical Diagram Rev A 76...
Страница 77: ...g033525 Sprayer System Schematic Rev A 77...
Страница 78: ...Notes...
Страница 80: ......