Note:
If the collected nozzle spray does not
meet the quantity in the
(page 37)
, check the nozzles, hoses, and fittings
for leaks, damage, or wear; clean or replace the
spray nozzles if needed.
Nozzle Flow Rate Chart
Use the nozzle flow rate charts determine spray
nozzle performance:
•
Nozzle flow rates at different spray-system
pressures
•
Worn or damaged spray nozzles
The following chart is based on the nozzle capacity
information chart provided with permission from
TeeJet® Technologies. Use the chart below or
reference the TeeJet® Technologies website to
determine if the flow rate of the sprayer nozzle is
within the specified flow rate (+/– 10%).
Note:
The chart information below is based on the
machine spraying water at 70
°
F (21
°
C).
Center Nozzle (red—narrow pattern) Flow
Rate Chart
Pressure
Flow Rate—New
Flow Rate—In Service
Nozzle
0.7 bar
(10 psi)
769
ml (26
fl oz)
/min
0.76 L (0.20
US gallon)
/min
0.68 to 0.75 L (0.18
to 0.22 US gallon)
/min
1.4 bar
(20 psi)
1065
ml (36
fl oz)
/min
1.06 L (0.28
US gallon)
/min
0.95 to 1.17 L (0.25
to 0.31 US gallon)
/min
2.1 bar
(30 psi)
1331
ml (45
fl oz)
/min
1.32 L (0.35
US gallon)
/min
1.19 to 1.45 L (0.32
to 0.39 US gallon)
/min
2.8 bar
(40 psi)
1508
ml (51
fl oz)
/min
1.51 L (0.40
US gallon)
/min
1.36 to 1.66 L (0.36
to 0.44 US gallon)
/min
Left and Right Nozzles (white—wide pattern)
Flow Rate Chart
Pressure
Flow Rate—New
Flow Rate—In Service
Nozzle
0.7 bar
(10 psi)
1508
ml (51
fl oz)
/min
1.51 L (0.40
US gallon)
/min
1.36 to 1.66 L (0.36
to 0.44 US gallon)
/min
1.4 bar
(20 psi)
2159
ml (73
fl oz)
/min
2.16 L (0.57
US gallon)
/min
1.94 to 2.38 L (0.51
to 0.63 US gallon)
/min
Left and Right Nozzles (white—wide pattern)
Flow Rate Chart (cont'd.)
2.1 bar
(30 psi)
2602
ml (88
fl oz)
/min
2.61 L (0.69
US gallon)
/min
2.35 to 2.87 L (0.62
to 0.76 US gallon)
/min
2.8 bar
(40 psi)
3017
ml
(102
fl oz)
/min
3.03 L (0.80
US gallon)
/min
2.73 to 3.33 L (0.72
to 0.88 US gallon)
/min
Determining Application Rate
Use the example results of the calculated speed,
spray width, and nozzle capacity to determine the
application rate.
Note:
The application rate may also be determined
by using the
Nozzle Flow Rate Chart (page 37)
,
along with the chemical manufacturer’s label of
recommendation.
The examples below are based on the following
information:
•
Average ground speed = 8.4 kph (5.2 mph)
•
Spray width = 2.7 m (108 inches)
•
Number of nozzles = 2
•
Nozzle capacity = 3.0 L/min (0.8 gpm)
Note:
The numbers 6 and 600 are constants used in
the formulas shown below.
Liter per 100 m
2
Application Rate
Single nozzle capacity (Lpm) x Number
of nozzles x 6
L
Speed (kph) x Spray width (m)
=
100 m
2
2.99 Lpm x 2 x 6
8.369 kph x 2.743 m
=
1.563 L/100 m
2
(1.5
qt/1,000 ft
2
)
Liter per Hectar Application Rate
Single nozzle capacity (Lpm) x Number
of nozzles x 600
L
Speed (kph) x Spray width (m)
=
hectar
2.99 Lpm x 2 x 600
8.369 kph x 2.743 m
=
156 L/hectar(16.7 gal/acre)
Note:
The numbers 544; 136; and 5,940 are
constants used in the formulas shown below.
37
Содержание 34215
Страница 75: ...Schematics g027149 Electrical Schematic Rev A 75...
Страница 76: ...g027148 Electrical Diagram Rev A 76...
Страница 77: ...g033525 Sprayer System Schematic Rev A 77...
Страница 78: ...Notes...
Страница 80: ......