Machine Faults
5
2
3
2
1
Faults
#11
Clear System Faults
--32.6 Ago
4
3
g340685
Figure 10
1.
Left/right button
4.
Fault items
2.
Down button
5.
Fault menu
3.
Menu/back button
The faults screen (
) will list all the machine electrical faults that have
occurred since the faults were last cleared from the InfoCenter. The faults will be
identified by a number and when the fault occurred. The faults that might occur
on the e1021/e1026 machine are listed in the
Fault Table (page 3–5)
.
The InfoCenter fault log can be cleared by selecting the clear system faults
menu item. The cleared faults will be removed from the InfoCenter but will be
retained in the TEC memory.
If a fault occurs during machine use, there may be a change in machine
functionality due to the fault. Should there be machine operation issues due to
a fault, a first step to remedy the issue would be to move the traction lever to
the NEUTRAL position, turn the key switch to the OFF position, and allow all
the machine functions to stop. Then, attempt to restart the machine to see if
operation has returned to normal. Some faults will be reset during the restart
and will then allow normal function. If a fault continues to occur, further system
evaluation and possible component repair or replacement will be necessary.
To return to the main menu screen from the faults screen, press the menu/back
button (as indicated by the
at the bottom of the screen).
Fault Table
Fault
Number
Fault Title
Controller
Affected
Fault Condition/Circuit
Description
Additional
Notes
Service Actions
1
Internal
TEC Fault
Master
The 13.3 V regulator on the
TEC is not able to maintain
regulation at an acceptable
voltage level.
This is an
onboard power
supply for the
TEC.
1.
Reboot the machine.
2.
Disconnect and reconnect the
battery.
3.
Look for short circuits in the
harness.
4.
Replace the TEC.
2
12Vdc
Supply
Fault
Master
The 12 V regulator on
the TEC cannot maintain
regulation at an acceptable
voltage level.
Most likely there is a short circuit
on the 12 V supply line that powers
the InfoCenter and the Slow-in-turn
switch.
Greensmaster
®
e1021/e1026
Page 3–5
Troubleshooting: Battery Charger Error and Fault Codes
20246SL Rev A
Содержание 04831
Страница 4: ...NOTES NOTES Page 4 Greensmaster e1021 e1026 20246SL Rev A ...
Страница 6: ...g340650 Figure 1 Model 04831 shown Preface Page 6 Greensmaster e1021 e1026 20246SL Rev A ...
Страница 14: ...Safety Safety and Instructional Decals Page 1 6 Greensmaster e1021 e1026 20246SL Rev A ...
Страница 46: ...Troubleshooting Battery Charger Error and Fault Codes Page 3 14 Greensmaster e1021 e1026 20246SL Rev A ...
Страница 136: ...Electrical System Service and Repairs Page 5 56 Greensmaster e1021 e1026 20246SL Rev A ...
Страница 162: ...Controls Wheels and Accessories Service and Repairs Page 6 26 Greensmaster e1021 e1026 20246SL Rev A ...
Страница 210: ...Universal Groomer Optional Service and Repairs Page 8 20 Greensmaster e1021 e1026 20246SL Rev A ...
Страница 213: ...Greensmaster e1021 e1026 Drawing 122 1647 Rev A Sheet 1 of 1 20246SL Rev A Page A 3 Electrical Schematic g361655 ...
Страница 214: ...Page A 4 20246SL Rev A Greensmaster e1021 e1026 Drawing 122 1734 Rev D Sheet 1 of 2 Wire Harness Drawing CV g361656 ...
Страница 215: ...Greensmaster e1021 e1026 Drawing 122 1734 Rev D Sheet 2 of 2 20246SL Rev A Page A 5 Wire Harness Drawing g361657 ...
Страница 216: ......