Operator Advisories
g340684
Figure 9
1.
Advisory name
2.
Advisory identification
Operator advisories are automatically displayed by the InfoCenter when a
machine function requires additional action (
). An advisory will not be
logged into the fault log.
The InfoCenter advisories include the following:
#201 (System Shutdown):
This advisory notifies the operator that the machine
is shutting down. Because the shutdown process takes some time, this advisory
is displayed so that an operator is aware of the shutdown and machine operation
is not available. The shutdown advisory will be displayed after the key switch is
turned OFF.
#202 (Low Battery Shutdown):
If the battery state of charge is too low for
continued machine operation, the low battery shutdown advisory will notify the
operator that the machine will automatically shutdown. Battery charging is
necessary before returning the machine to normal operation.
#203 (Energy Saving Mode Active):
If the battery state of charge is too low for
normal machine operation, the energy saving mode active advisory will notify
the operator that the machine is operating with reduced functionality (cutting unit
disengaged and reduced traction speed). Battery charging is necessary before
returning the machine to normal operation.
#204 (Energy Saving Mode Warning):
If the battery state of charge is too low
for normal machine operation, the energy saving mode warning advisory will
notify the operator that the machine will start operating with reduced functionality
(cutting unit disengaged and reduced traction speed) in approximately 30
seconds. Battery charging is necessary before returning the machine to normal
operation.
#207 (Motor Current Limit):
This advisory notifies the operator that the electric
motor is already running at maximum current and cannot deliver any additional
performance. For example, the motor current limit advisory would be displayed
if the speed control was increased when the motor was already providing
maximum performance.
#208 (Motor Not Ready):
This advisory notifies the operator that the electric
motor is not ready to deliver the performance.
#210 (High Power Consumption Run Time Reduced):
The high power
consumption identifies that electric motor draw is excessive and will reduce the
run time of the machine. Excessive cutting unit bedknife contact or accessory
use may generate this advisory.
Greensmaster
®
e1021/e1026
Page 3–3
Troubleshooting: Battery Charger Error and Fault Codes
20246SL Rev A
Содержание 04831
Страница 4: ...NOTES NOTES Page 4 Greensmaster e1021 e1026 20246SL Rev A ...
Страница 6: ...g340650 Figure 1 Model 04831 shown Preface Page 6 Greensmaster e1021 e1026 20246SL Rev A ...
Страница 14: ...Safety Safety and Instructional Decals Page 1 6 Greensmaster e1021 e1026 20246SL Rev A ...
Страница 46: ...Troubleshooting Battery Charger Error and Fault Codes Page 3 14 Greensmaster e1021 e1026 20246SL Rev A ...
Страница 136: ...Electrical System Service and Repairs Page 5 56 Greensmaster e1021 e1026 20246SL Rev A ...
Страница 162: ...Controls Wheels and Accessories Service and Repairs Page 6 26 Greensmaster e1021 e1026 20246SL Rev A ...
Страница 210: ...Universal Groomer Optional Service and Repairs Page 8 20 Greensmaster e1021 e1026 20246SL Rev A ...
Страница 213: ...Greensmaster e1021 e1026 Drawing 122 1647 Rev A Sheet 1 of 1 20246SL Rev A Page A 3 Electrical Schematic g361655 ...
Страница 214: ...Page A 4 20246SL Rev A Greensmaster e1021 e1026 Drawing 122 1734 Rev D Sheet 1 of 2 Wire Harness Drawing CV g361656 ...
Страница 215: ...Greensmaster e1021 e1026 Drawing 122 1734 Rev D Sheet 2 of 2 20246SL Rev A Page A 5 Wire Harness Drawing g361657 ...
Страница 216: ......