GTM1 User manual V-2020-08-12
43 |
E N
Wiegand keypad programming
iButton probe programming
Go to SERA2> System Options> General System Options
Press “Start iButton/ RFID/Phone programming mode
Go to SERA2> Users/ Access control
Touch RFID cards to the reader
Go to SERA2> System Options> General System Options
Press “Stop Programming” button
Go to SERA2> RT Testing & Monitoring> Hardware
Press “Start Monitoring” button
Go to SERA2> RT Testing & Monitoring> Security Alarm Panel/
Access
You will see real time system status
Go to SERA2> System Options> General System Options
Set 1W (1- Wire Bus) to Dallas 1-Wire Bus DS1990A/ DS18b20
Press “Write” in the command line
Figure 87 SERA2> System Options> General System Options
Go to SERA2> System Options> General System Options
Press “Start iButton/ RFID/Phone programming mode”
Figure 88 SERA2> System Options> General System Options
Go to SERA2> Users/ Access control
Touch iButton keys to the probe
Go to SERA2> System Options> General System Options
Press “Stop Programming” button
Figure 89 SERA2> Users/ Access Control> Users
Go to SERA2> RT Testing & Monitoring> Hardware
Press “Start Monitoring” button
Go to SERA2> RT Testing & Monitoring> Security Alarm Panel/
Access
You will see real time system status
4.8.2
Enter iButton, RFID, Phone numbers to the memory of the module
If you want to edit existing configuration,
You have to read it (press “Read” in the command line)
Edit settings,
Write edited configuration (press “Write” in the command line)
Figure 85 SERA2> System Options> General System Options
Figure 86 SERA2> Users/ Access Control> Users