GTM1 User manual V-2020-08-12
39 |
E N
Figure 74Outputs (PGM) window
This output could be controlled as fallowing:
-
If the user has right to ARM/DISARM system, it always has access to this output.
-
If the user
has not the right to ARM/DISARM the system
(field near ARM/DISARM is not marked (Sera2> User/ Access control)),
the
user can access this output only if system is Disarmed.
Figure 75User/ Access control window
-
If access is granted by user, 421 event Access granted is stored into the log. If not Access denied event 422 is stored to the log (Sera2>
Events Log)
-
if output will have definition [
Automation / CTRL
] it also can be controlled by user in any way but it will not generate 421 and 422 events
Event log e.g.
1853 Event:1234:1:401:01:001 Time:2017-08-20 14:42:36 Note: , Open by User, User:001, Name:Master
1852 Event:1234:1:422:00:001 Time:2017-08-20 14:41:41 Note: , Access Gained by, User:001, Name:Master
1851 Event:1234:1:406:01:001 Time:2017-08-20 14:41:27 Note: , Cancel, User:001, Name:Master
Outputs
can be controlled in “Automation & Access control”, “Access Gained” modes.
8.
If you need to control outputs by short call or SMS, go to Sera2> Users/ Access control window and enter phone numbers of users, who will be
able to control selected outputs via free short call.
9.
Write configuration by pressing write icon
In order to control big power alternating current equipment, it is comfortable to use solid state relays.
Refer to:
Error! Reference source not found.
Figure 76Users/ Access control window