GTM1 User manual V-2020-08-12
27 |
E N
Real time events list
Go to SERA2>
RT Testing & Monitoring> Event Monitoring
Figure 43SERA2> RT Testing & Monitoring> Event Monitoring
4.2.9
How to read event log from internal memory of the module?
Read events log
Go to SERA2> Events Log
Press “Read Event Log” button
Figure 44 SERA2> Event Log
Figure 45 SERA2> Event Log
4.2.10 How to set SMS alarms?
If you want to edit existing configuration, You have to read
it (press “Read” in the command line)
Edit settings,
Write edited configuration (press “Write” in the command line)
Alarm SMS to the mobile phone
Go to SERA2> GSM Communication > SMS/ DIAL
reporting
Enter your phone number
Mark alarm events
Press “Write” in the command line
Figure 46 SERA2> GSM Communication> SMS DIAL Reporting
4.2.11 Burglar Alarm sensor zones wiring EOL NO NC
The module GTM1 has:
-
IN1/D1: 0-30V
-
IO1and IO2 programmable selectable input or output
-
IO1: 0-30V
-
IO2: 0-30V
-
IO3/D0 programmable selectable
-
IO3/D0: 0-30V analog input (zone or sensor)
-
IO3/D0: 0-20mA 4-20mA current loop sensor
-
2- wire Smoke Detector (Fire urrent loop)
Inputs c
an be used or use it as security system‘s zones with selectable type: NC/NO/EOL/EOL+TAMPER.