Use and Maintenance Manual - Series V8 E V10 E
Page 68
7.2.12.
Operation check of dead-man pedal safety system
The platform dead-man pedal is for enabling the operation controls of the machine on the platform control panel.
Check operation at least once a year.
To check the “dead
-
man” PEDAL:
▪
Move the drive joystick forward and backward in sequence, WITHOUT PRESSING THE “DEAD
-
MAN” PEDAL.
▪
check that the machine does not perform any movement.
▪
hold down the dead-man pedal for more than 10 seconds
▪
With the pedal pressed, move the joystick forward and backward in sequence.
▪
check that the machine does not perform any movement.
If the device works properly, no machine movement is possible on the platform control panel unless you press the “dead
-
man” pedal beforehand. If this is pressed for more than
10 seconds and no operation is performed, all movements are
disabled; to operate the machine again, release the dead-man pedal and press it again.
The condition of the switch is indicated by the green led in the platform:
▪
Steady green led lit up
enabled control panel
▪
Flashing green led lit up
disabled control panel
7.2.13.
Operation check of “dead
-
man” button safety system (optional).
The platform dead-man button (alternative to the pedal) is for enabling the operation controls of the machine from the
platform control station.
Check operation at least once a year.
To check the dead-man BUTTON:
▪
move the drive joystick forward and backward in sequence, WITHOUT PRESSING THE DEAD-MAN BUTTON
▪
check that the machine does not perform any movement
▪
press and release the dead-man button and wait three seconds
▪
move the joystick forward and backward in sequence
▪
check that the machine does not perform any movement
If the device works properly, no machine manoeuvre is possible from the platform control panel unless you press the dead-
man button beforehand. If this is pressed for more than 2 seconds and no operation is performed, all movements are
disabled; to operate the machine again, press and release the dead-man pedal again and activate a control within 2
seconds.
The condition of the switch is indicated by the green led in the platform:
▪
Steady green led lit up
enabled control panel
▪
Flashing green led lit up
disabled control panel
Содержание Airo V Series
Страница 14: ...Use and Maintenance Manual Series V8 E V10 E Page 14...
Страница 17: ...Use and Maintenance Manual Series V8 E V10 E Page 17...
Страница 75: ...Use and Maintenance Manual Series V8 E V10 E Page 75...
Страница 94: ...Use and Maintenance Manual Series V8 E V10 E Page 94...
Страница 95: ...Use and Maintenance Manual Series V8 E V10 E Page 95...
Страница 96: ...Use and Maintenance Manual Series V8 E V10 E Page 96...
Страница 97: ...Use and Maintenance Manual Series V8 E V10 E Page 97...
Страница 98: ...Use and Maintenance Manual Series V8 E V10 E Page 98...
Страница 100: ...Use and Maintenance Manual Series V8 E V10 E Page 100...