Use and Maintenance Manual - Series V8 E V10 E
Page 46
5.5.
Machine stop
5.5.1.
Normal stop
During the normal use of the machine, releasing the controls or the dead-man pedal in the platform, the operation will be
stopped. Stop occurs within a time limit set in the factory, which guarantees smooth braking.
5.5.2.
Emergency stop button
Should it be necessary, the operator may immediately
stop all machine functions on both platform and ground
control panel.
On the platform control panel:
▪
press the emergency stop button on the control
panel and the machine is turned off.
▪
by releasing the dead-man pedal, the operation
will be stopped.
On the ground control panel:
▪
press the emergency stop button on the ground
control panel (if any) and the machine will be
turned off;
▪
by pulling out the power connector represented
in the figure beside, the machine power is cut out
(power circuit cut-out).
Fig. 13
To resume the operations:
On the platform control panel:
▪
turn the emergency stop button of 1/4 turn clockwise;
On the ground control panel:
▪
turn the emergency stop button of 1/4 turn clockwise and insert the connector thoroughly to power the machine
again.
WARNING
The emergency stops are not active during the function of emergency recovery FACTORY
OVERRIDE.
Содержание Airo V Series
Страница 14: ...Use and Maintenance Manual Series V8 E V10 E Page 14...
Страница 17: ...Use and Maintenance Manual Series V8 E V10 E Page 17...
Страница 75: ...Use and Maintenance Manual Series V8 E V10 E Page 75...
Страница 94: ...Use and Maintenance Manual Series V8 E V10 E Page 94...
Страница 95: ...Use and Maintenance Manual Series V8 E V10 E Page 95...
Страница 96: ...Use and Maintenance Manual Series V8 E V10 E Page 96...
Страница 97: ...Use and Maintenance Manual Series V8 E V10 E Page 97...
Страница 98: ...Use and Maintenance Manual Series V8 E V10 E Page 98...
Страница 100: ...Use and Maintenance Manual Series V8 E V10 E Page 100...