Use and Maintenance Manual - Series V8 E V10 E
Page 34
5.2.3.1.
Display messages
Any alarm and/or system error codes can be displayed in the following form:
Example of error code:
03 A 22
The first
2
figures relate to the concerned device:
-
03
= MASTER controller
-
04
= SLAVE controller
-
08
= board on platform CAN TILLER
-
16
= MDI indicator.
The Letter
A
means alarm / error.
The last
2
digits specify the particular type of alarm or error.
If there are multiple alarms/errors, they are displayed one at a time, in rotation.
Table of codes of alarm/error:
MDI code = displayed on the indicator
ZAPI code = displayed on the calibration console, if connected to the system.
For several diagnostic tasks described in the table, it is necessary to connect the Smart ZAPI console
Cod.
Mdi
Cod.
Zapi
Message on Smart
Console
Description
Diagnostics / Possible solution
0
66
BATTERY LOW Battery discharged <10%
Recharge the battery.
If this is not solved, use a voltmeter to measure the battery
voltage and compare it with the value in parameter
BATTERY VOLTAGE. If they are different, adjust the value
of the ADJUST BATTERY parameter.
0
247
DATA ACQUISITION Current gain acquisition
The alarm ends when the acquisition is finished.
0
249
CHECK UP NEEDED Maintenance request alert
Simply select the option CHECK UP DONE on value ON
after maintenance has been performed.
8
8
WATCHDOG
Safety logic error
This alarm may be caused by a hardware fault in one of the
two (or both) of the multi-vibrators or due to a software
execution problem.
In both cases it is a fault inside the controller, which must be
replaced.
8
231
WATCHDOG#2 Safety logic error
This alarm may be caused by a hardware fault in one of the
two (or both) of the multi-vibrators or due to a software
execution problem.
In both cases it is a fault inside the controller, which must be
replaced.
11
211
STALL ROTOR
Drive rotor locked / encoder
signal not received
Check on TESTER menu if during a drive request the
FREQUENCY and ENCODER signs are equal and both
different from zero.
12
239
CONTROLLER MISM. Software version incompatible
with the controller
This type of error is not related to external components, so if
present, replace the controller.
13
208
EEPROM KO EEPROM memory error
Try to perform a CLEAR EEPROM operation (refer to the
console manual).
Turn the system off and on. If the alarm reoccurs, replace
the controller.
If the alarm disappears, the parameters stored during
calibration will be replaced by the default parameters.
13
209
PARAM RESTORE Loading parameter sets made
If a procedure of CLEAR EEPROM was carried out before
the last ignition, this warning means that the EEPROM has
been correctly deleted: A new command clears the alarm.
If this alarm goes off at power-up, without any previous
CLEAR EEPROM procedure, there might be a problem in
the controller, which must be replaced.
17
17
LOGIC FAILURE #3 Error in logic: hardware problem This type of error is not related to external components, so if
present, replace the controller.
Содержание Airo V Series
Страница 14: ...Use and Maintenance Manual Series V8 E V10 E Page 14...
Страница 17: ...Use and Maintenance Manual Series V8 E V10 E Page 17...
Страница 75: ...Use and Maintenance Manual Series V8 E V10 E Page 75...
Страница 94: ...Use and Maintenance Manual Series V8 E V10 E Page 94...
Страница 95: ...Use and Maintenance Manual Series V8 E V10 E Page 95...
Страница 96: ...Use and Maintenance Manual Series V8 E V10 E Page 96...
Страница 97: ...Use and Maintenance Manual Series V8 E V10 E Page 97...
Страница 98: ...Use and Maintenance Manual Series V8 E V10 E Page 98...
Страница 100: ...Use and Maintenance Manual Series V8 E V10 E Page 100...