Use and Maintenance Manual - Series V8 E V10 E
Page 38
54
19
LOGIC FAILURE #1 Error in logic: power supply
undervoltage or overvoltage
Alarm displayed at start-up or in standby; in these cases, the
error is very likely due to undervoltage, then it is advisable to
check:
A) Descendant pulse of the key input signal (below the
undervoltage threshold) due to external loads, such as the
starting of DC/DC converters, relays, contactors or
excitation of solenoids;
B) If there is no voltage transient on the power supply line
and the alarm is present each time the system is turned on,
the error is likely to be due to the internal hardware, then the
controller must be replaced.
55
18
LOGIC FAILURE #2 Error in logic: hardware problem This type of error is not related to external components, so if
present, replace the controller.
56
217
PUMP I NO ZERO Pump feedback current outside
the allowed range
This type of error is not related to external components, so if
present, replace the controller.
60
60
CAPACITOR
CHARGE
Power capacitors cannot be load A) An external load absorbs current and does not allow the
power capacitor circuit to be charged. Check if there are
lamps or DC-DC converters connected in parallel.
B) The charge resistance is open. Insert a power resistance
between the contacts of the line contactor:
If the alarm disappears, it means that the resistance inside
the controller is damaged.
C) The charging circuit inside the controller is faulty.
D) The controller power section has a problem.
61
250
THERMIC SENS. KO Controller thermal sensor
malfunction
This type of error is not related to external components, so if
present, replace the controller.
62
62
TH. PROTECTION
Operation in thermal protection -
controller overheating
Improve the cooling of the controller.
If the alarm is displayed when the controller is cold, the
possible causes are a failure in the thermal sensor or in the
logic board. In the latter case, the controller must be
replaced.
63
204
WAIT MOT.P STILL Waiting for the pump motor stop If the motor connected to -P is still running, wait until it has
fully stopped.
Otherwise, within 30 seconds the alarm "PUMP VMN NOT
OK” will appear.
Refer to the item "PUMP VMN NOT OK".
64
238
TILLER ERROR
Dead-man circuit error
Check wiring of CAN # 1 and CAN # 29 by means of a
voltmeter. If the status of these inputs is right, there might be
problem in the controller, which must be replaced.
65
65
MOTOR TEMPERAT. Drive motor overheating
Check the reading of the thermal sensor inside the motor
(by reading the value of the parameter MOTOR
TEMPERATURE in the MOTOR menu reading in the
TESTER menu);
check the ohmic value of the sensor and the wiring.
If the sensor is operating correctly, improve the air-cooling of
the motor.
If the alarm is displayed when the motor is cold, the problem
is inside the controller, which must be replaced.
67
218
SENS MOT TEMP KO
Motor thermal sensor
malfunction
Check the correct connection of the temperature sensor of
the motor.
If the current sensor is connected correctly, try replacing it.
If the problem persists, try replacing the controller.
68
222
SMART DRIVER KO Positive output for electric brake
damaged
A) It is recommended that the wiring be checked in order to
verify if the Smart driver output, CNB # 1, is short-circuited
with -Batt.
B) If, even after disconnecting the wire from the connector
pin, the output remains at low voltage, the problem is inside
the controller and the Smart Driver may be damaged.
The controller must be replaced
Содержание Airo V Series
Страница 14: ...Use and Maintenance Manual Series V8 E V10 E Page 14...
Страница 17: ...Use and Maintenance Manual Series V8 E V10 E Page 17...
Страница 75: ...Use and Maintenance Manual Series V8 E V10 E Page 75...
Страница 94: ...Use and Maintenance Manual Series V8 E V10 E Page 94...
Страница 95: ...Use and Maintenance Manual Series V8 E V10 E Page 95...
Страница 96: ...Use and Maintenance Manual Series V8 E V10 E Page 96...
Страница 97: ...Use and Maintenance Manual Series V8 E V10 E Page 97...
Страница 98: ...Use and Maintenance Manual Series V8 E V10 E Page 98...
Страница 100: ...Use and Maintenance Manual Series V8 E V10 E Page 100...