7.2.5.
Drive reduction gear oil level check and change
The oil level should be checked at least once a year. Place
the machine so as to have the two caps (
A
and
B
) in the
position shown in the picture aside (in a few cases it is
necessary to remove the driving wheels to access the a.m.
caps). Check the level by means of cap (
A
). Oil check must
be carried out when the oil is hot. The level is correct when
the reduction gear body is full of oil up to the cap limit (
A
).
Should a lubricant volume higher than 10% be topped up,
check that there is no oil leakage in the system. Do not mix
different types of oil, of the same or of different brands. Do
not mix mineral oils and synthetic oils.
The oil must be changed the first time after 50-100 working
hours, and afterwards after every two years. Depending on
the actual operating conditions, these intervals may be
varied for each single case.
Fig.22
While changing the oil it is advisable to wash the internal part of the cover with a fluid recommended by the lubricant
producer. To avoid sludge deposits, the oil must be changed when the reduction gear is hot. To change the oil, unscrew
cap
B
, and place a container of a 2-litre capacity under it. Empty the reduction gear body completely, clean it as
described above and then fill it up to the limit level of cap
A
through the same hole (for max. capacity see following
table).
HYDRAULIC SYSTEM OIL
BRAND
TYPE
REQUIRED QUANTITY
Drive
SYNTHETIC OILS
0,4 litres
ESSO
Compressor Oil LG 150
AGIP
Blasia S 220
CASTROL
Alpha SN 6
IP
Telesia Oil 150
BIODEGRADABLE OILS - OPTIONAL
PANOLIN
Biogear 80W90
7.2.5.1
Checks in the use of synthetic biodegradable oil in drive reduction gears (Optional)
Quarterly or every 500 hours check the oil level. In case of need top up. If you notice that more than 10% of oil lacks in the
reduction gear, check if there are any leaks.
Change the oil in the rotation reduction gear after the first 100 hours of operation and then every 6000 hours or every 3
years. Depending on the actual operating conditions, these intervals may change.
When changing the oil, it is recommended that you run a wash cycle inside the cover.
Change the oil when the reduction gear is hot. Mixtures of different oils (either biodegradable or mineral) even of the same
brand are not allowed.
During oil change or topping up, do not discard the hydraulic oil in the environment.
Содержание Airo V Series
Страница 14: ...Use and Maintenance Manual Series V8 E V10 E Page 14...
Страница 17: ...Use and Maintenance Manual Series V8 E V10 E Page 17...
Страница 75: ...Use and Maintenance Manual Series V8 E V10 E Page 75...
Страница 94: ...Use and Maintenance Manual Series V8 E V10 E Page 94...
Страница 95: ...Use and Maintenance Manual Series V8 E V10 E Page 95...
Страница 96: ...Use and Maintenance Manual Series V8 E V10 E Page 96...
Страница 97: ...Use and Maintenance Manual Series V8 E V10 E Page 97...
Страница 98: ...Use and Maintenance Manual Series V8 E V10 E Page 98...
Страница 100: ...Use and Maintenance Manual Series V8 E V10 E Page 100...