Reset Factory Default Settings
to clear recent log history using the web-GUI.
16.17
RS232 Data Configuration
The codec supports both in-band and out-of-band data depending on the algorithm you are using.
RPTP data is automatically enabled when using the Tieline Music or MusicPLUS algorithms over
IP. It is also possible to enable synchronized out-of-band data using any algorithm.
Algorithm Selected
IP
Tieline Music and MusicPLUS
·
In-band RPTP data enabled automatically
·
Synchronized out-of-band data can be enabled and
disabled
All other algorithms
·
Synchronized out-of-band data can be enabled and
disabled
The codec can be connected to external devices and send RS232-compatible data via the serial
port on the rear panel of the codec. To enable RS232 data within a connection, select
Enable
Auxiliary Data
when creating a program in the
Programs panel
wizard. Alternatively, select using
the codec
Setup
menu (see
Bridge-IT XTRA Relays and RS232 Data
).
Setting RS232 Data Rates and Flow Control
1. Open the web-GUI and click the
Settings
symbol at the top of the screen to display the
Settings panel
.
2. Click the
Options
button.
3. Click the
Baud rate
drop-down menu arrow to select the serial port baud rate which matches the
baud rate of the external device connected to the RS232 port on the codec.
4. Click to select the
Enable flow control
check box and enable flow control, then click
Save
settings
.
Important Notes:
·
When connecting to G3 codecs over IP only in-band data is available via the Music and
MusicPLUS algorithms.
·
Use firmware higher than 2.8.xx in the Bridge-IT, Genie and Merlin families of codecs to
enable auxiliary data over multicast connections.
·
It is important to enable serial port flow control as it regulates the flow of data through the
serial port. If disabled, data will flow unregulated and some may be lost.
·
Ensure you configure the serial port baud rate to match the setting of the external device
to which you are connecting. Ideally the settings on both codecs should match, or you
could have data overflow issues.
·
Only the dialing codec needs to be configured to send RS232 data. Session data sent
from the dialing codec will configure all other compatible codecs (non-G3) when you
connect.
Содержание Bridge-IT XTRA
Страница 18: ...18 Bridge IT XTRA Manual Tieline Pty Ltd 2015 Codec Menu Overview...
Страница 19: ...19 Tieline Pty Ltd 2015 Bridge IT XTRA Manual Connect Menu...
Страница 20: ...20 Bridge IT XTRA Manual Tieline Pty Ltd 2015 IP Setup Menu Navigation...
Страница 21: ...21 Tieline Pty Ltd 2015 Bridge IT XTRA Manual Settings Menu...