8. Notes for special Editors and DVEs
Diamond digital
70
Not tested. See A57.
RS232 protocol
Sequence selection, fader transition possible, no scaling necessary, runs only at
9600bps.
Select DVE A53D as port protocol for PORT1 (RS232) within switcher setup.
Enable remote control on A53 keyboard.
Use cable with following connections:
Diamond
9-polig
25-polig
Abekas A53D
2
3
8
2
5
7
4
7
TxD
RxD
RxD
RTS
CTS
GND
TxD
GND
5
4
RTS
CTS
Set Charisma Remote protocol to ”BVW75”. Select ”DVE CHARIS” as port protocol
within switcher setup. Runtime is set to 30s from DD10 (may fail, if runtime is stored
with effect).
Problems may arise with extremely long timelines. With earlier software versions
(Charisma), sequence selection from switcher had to be confirmed on local panel.
A special RS422 cable with one male and one female connector and 1:1 connec-
tions has to be used.
No information.
Model-100 protocol
Set runtime to 30s, fader play, sequence selection.
Do not stop ongoing sequences or manual transitions!
On manual sequence run from switcher as well as from local console events stored
in the sequence (e.g. freeze, E-MEM-recall etc.) can be omitted.
Select protocol ”DVE DPM” in the switcher setup, Model-100 protocol on
DPM100/700.
Standard RS422 cable can be used.
VTR protocol
Is of no use at all.
Control panel protocol
Not implemented.
ABEKAS A53D
QUESTECH
CHARISMA
GVG-DPM 100
GVG-DPM 700
Содержание DD10
Страница 1: ...DD5 DD10 DD20 DD30 Production Switchers Planning Installation BTS CAM1 CAM1 ...
Страница 9: ...About this manual Diamond digital ...
Страница 27: ...1 General Diamond digital 18 ...
Страница 58: ...5 Connection and Startup Diamond digital 49 ...
Страница 105: ...6 Initial Installation Diamond digital 96 ...
Страница 163: ...10 Block diagrams Diamond digital 154 ...
Страница 165: ...10 Block diagrams Diamond digital 156 ...
Страница 167: ...10 Block diagrams Diamond digital 158 ...