5. Connection and Startup
Diamond digital
41
5.
CONNECTION AND STARTUP
5.1
CONNECTING POWER AND EARTH LINES
The units of the switcher family Diamond digital have been completely checked in
the factory and are in conformity with the safety regulation EN60950 (VDE0805)
when leaving the factory.
The respective switcher electronics (E-box) is located in a 19-inch case, suitable
for being installed in a DIN or 19-inch cabinet.
When mounting into a cabinet, care should be taken to allow for adequate horizon-
tal air circulation. The maximum ambient temperature must not 40
°
C dur-
ing operation.
PERMANENT EARTH CONNECTION
Due to their high leakage currents (>3.5 mA), the electronics boxes DD20 and
DD30 must be permanently connected with the earth terminal of the equipment
cabinet. For this purpose, the connector panel is provided with a separate earth
cable (green/yellow, 4 mm
2)
with a length of 2.80 m.
Make the earth connections always before applying mains power!
For this purpose, the connector panel also carries the following warning note:
BTS
Broadcast Television Systems GmbH
EARTH
ESSENTIAL BEFORE
CONNECTING SUPPLY
CONNECTION
HIGH LEAKAGE CURRENT
POWER CONNECTION
Prior to connecting the switcher components to the line voltage make sure that the
power supplies of control panel and electronics box are adjusted to the correspond-
ing primary voltage. The factory-adjusted voltage is indicated on the respective
connector panel (E-box, control panel) were also the type label is fastened.
Note for installing DD20 and DD30:
When operating within the line voltage range of 115V, mains-caused under-
voltages may effect an increased current consumption and as a conse-
quence an activation of the preceding fuses!
For this reason, the electronics boxes of the mixers DD20 and DD30 must be
only operated at a line voltage of 230V. When leaving the factory, the power
supply units are adjusted to the respective voltage and marked accordingly.
For switching over to another line voltage, see the corresponding section in this
manual.
In order to be able to make quickly deadly the mixer in the case of malfunc-
tion, the mains cabling of the mixer must be interruptable and at any time ac-
cessible.
Содержание DD10
Страница 1: ...DD5 DD10 DD20 DD30 Production Switchers Planning Installation BTS CAM1 CAM1 ...
Страница 9: ...About this manual Diamond digital ...
Страница 27: ...1 General Diamond digital 18 ...
Страница 58: ...5 Connection and Startup Diamond digital 49 ...
Страница 105: ...6 Initial Installation Diamond digital 96 ...
Страница 163: ...10 Block diagrams Diamond digital 154 ...
Страница 165: ...10 Block diagrams Diamond digital 156 ...
Страница 167: ...10 Block diagrams Diamond digital 158 ...