6. Initial Installation
Diamond digital
76
DIL switch MONITOR
Switch T4 for adjusting the screen color of the menu monitor (EGA or
VGA).
See the section ”Connecting a menu monitor”.
LED row STATUS
Status indicator (G11...G18) of the power-up test.
See the section ”Error Diagnosis” in the service manual.
LED
Test
G11
RAM-Test
G12
Service-Term (DUART 1 Channel B)
G13
INT3-Test
G14
EPROM-Test
G15
DUART 1 Channel A, DUART 2 Channel A + B
G16
INT2-Test
G17
Hardware I/O
G18
unused
At the beginning of the test, all used LEDs are lit. After having passed
the test, the associated LED is switched off. Switching-off is made
from the left to the right. This, however, is hardly perceptible when
powering up, since the tests – except for the RAM and EPROM
checks – are very fast.
If a certain test failed, the LED G18, stays lighted. An exception is the
lowest LED which indicates during normal operation the error ”NO
CHEAPERNET COMMUNICATION” in addition to the running light.
When all tests have been passed, a kind of running light appears on
the LED row. This shows immediately whether the controller operates
in the normal mode.
The running light is operated by the microcomputer only if it is not oc-
cupied with something more important.
Thus, the speed of the running light allows a qualitative judge-
ment of the the computer activity.
Содержание DD10
Страница 1: ...DD5 DD10 DD20 DD30 Production Switchers Planning Installation BTS CAM1 CAM1 ...
Страница 9: ...About this manual Diamond digital ...
Страница 27: ...1 General Diamond digital 18 ...
Страница 58: ...5 Connection and Startup Diamond digital 49 ...
Страница 105: ...6 Initial Installation Diamond digital 96 ...
Страница 163: ...10 Block diagrams Diamond digital 154 ...
Страница 165: ...10 Block diagrams Diamond digital 156 ...
Страница 167: ...10 Block diagrams Diamond digital 158 ...