2. Technical Data
Diamond digital
21
2.1.6
ENVIRONMENTAL DATA
– Storage temp. E-box
- 20
o
C - + 70
o
C
– Storage temp. contr. pan.
0
o
C - + 70
o
C (32
o
- 158
o
F)
– Operating temp. E-box
+ 5
o
C - +35
o
C
For operation within specs
+ 10
o
C - +30
o
C
Op. temp. control panel
+ 5
o
C - +35
o
C
– Ventilation E-box
140 m
3
/h
– Relative humidity
80 % non-condensing
– Electromagn. compatibility (EMC) EN 55022, Class B
FCC (47CFR) PART 15 Subp J Class A
IEC 801-3, 3 V/m
– ESD
IEC 801-2, 8 kV
2.1.7
MECHANICAL DATA
– Dimensions E-box
212(h) x 483(w) x 470(d) mm, (19”, 5 RU)
1 RU under the electronics box has to be
left free for ventilation and slide-in rails
– Dimensions contr. panel
373(h) x 482(w) x 97.5(d) mm
– Cutout meas. contr. panel
449 x 358 mm
– Ventilation E-box
Suction port: left side panel
Blow-out port: rear top
– Weight E-box
20 kg
– Weight control panel
7 kg
– Mechanical stress
vibration IEC 68-2-6,
shock IEC 68-2-29
tilt fall IEC 68-2-31,
– Color E-box
dark mushroom, Philips 10709/G8
– Color control panel
ultra dark grey, Philips 10714/G8
Содержание DD10
Страница 1: ...DD5 DD10 DD20 DD30 Production Switchers Planning Installation BTS CAM1 CAM1 ...
Страница 9: ...About this manual Diamond digital ...
Страница 27: ...1 General Diamond digital 18 ...
Страница 58: ...5 Connection and Startup Diamond digital 49 ...
Страница 105: ...6 Initial Installation Diamond digital 96 ...
Страница 163: ...10 Block diagrams Diamond digital 154 ...
Страница 165: ...10 Block diagrams Diamond digital 156 ...
Страница 167: ...10 Block diagrams Diamond digital 158 ...