background image

X450-G2 Series Switch Quick Reference

For complete installation instructions see the 

Extreme Networks 

Summit Family Hardware Installation Guide 

at: 

www.extremenetworks.com/documentation

Hardware Components

Figure 1

 and 

Figure 2

 display the panel ports, LEDs, and hardware 

components on the X450-G2 Series switches. See the 

Extreme 

Networks Summit Family Hardware Installation Guide

 for component 

details.

Figure 1

 X450-G2 Switch Front Panels

Figure 2

 X450-G2 Switch Back Panels

Installation Site Requirements

The installation site must be within reach of the network cabling and 
meet the requirements listed below:

Appropriate grounded power receptacles must be located within 6 
feet of the site.

A temperature of between 0°C (32°F) and 50°C (122°F) must be 
maintained at the installation site with fluctuations of less than 10°C 
(18°F) per hour.

Installing the system as described in this guide meets the protective 
earth grounding requirements of the National Electrical Code (NEC) 
UL 60950 and IEC 60950 standards. If it is necessary to use an 
alternative grounding method, connect a 14 AWG wire between the 
ground screw on the chassis and a nearby building ground point. 

Handling the Switch

To prevent electrostatic damage, attach an electrostatic discharge 
(ESD) wrist strap to your wrist before handling the switch.
Unpack the switch as follows:
1

Remove the packing material protecting the switch.

2 Remove the tape seal on the non-conductive bag to remove the 

switch.

3 Perform a visual inspection of the switch for any signs of physical 

damage. Contact Extreme Networks if there are any signs of 
damage. See 

“Getting Help”

 for more information on contacting 

Extreme Networks. 

Electrical Hazard: 

Only qualified personnel should perform 

installation procedures.

Risques d'électrocution: 

Seul un personnel qualifié doit effectuer 

les procédures d'installation.

1

Stack LED

5

1000BASE-X SFP or 
10G SFP+ ports

9

AC power input 
connector

2

Console/Management 
ports

6

21 Gb stacking port 
(QSFP+)

10

Grounding screw

3

USB port

7

Redundant power 
supply (RPS) connector

11

PoE+ power supply 
bays

4

10/100/1000BASE-T or 
10/100/1000BASE-T 
PoE+ ports

8

Front-to-back fan 
module slot

Caution: 

To ensure proper ventilation and prevent overheating, 

leave a minimum clearance space of 5.1 cm (2.0 in.) on both sides of 
the device.

Warning: 

A readily accessible disconnect device shall be 

incorporated in the building installation wiring.

Avertissements: 

Incorporez sur le circuit de câblage un dispositif de 

déconnexion facilement accessible.

Caution: 

The switch can be damaged by electrostatic discharge.

PoE+ Switch

Non-PoE Switch

Installing the Summit X450-G2 Series Switch

You can install a Summit X450-G2 Series switch in a rack. There are four 
possible rack mounting configurations, depending upon whether:

The switch I/O ports or the power supply side of the device face 
front

The device is mounted flush with the rack posts or mid-mounted

Stacking Switches

Up to eight X450-G2 Series switches can be stacked together and 
connected, allowing the entire stack to operate with a single IP address. 
You can use the following ports for stacking:

21Gb QSFP+ stacking ports

 (

Figure 2

, callout 7)—For non-PoE 

X450-G2 Series switches only. The stacking ports require QSFP+ 
direct attach passive copper cables, which are available in multiple 
lengths. You must order these cables separately.

Front panel 1GbE or 10GbE ports

 (

Figure 1

 callout 5)—Use two of 

the front panel 1GbE SFP or 10GbE SFP+ ports. If your Summit 
X450-G2 Series switch has 10GbE ports, you can use SummitStack-
V to create a stack that includes other Summit switch models 
equipped with 10GbE SFP+ ports. 

For complete information about stacking, refer to the 

Extreme 

Networks Summit Family Hardware Installation Guide.

Securing the Switch to the Rack

To secure the Summit X450-G2 Series switch to the rack:
1

Attach the mounting brackets to the sides of the switch using six 
screws for each bracket. 

2 Align the rack mount ear holes with the front rack post holes.
3 Secure the Summit X450-G2 Series switches to each rack post with 

at least two screws or fasteners appropriate to the rack.

Installing Pluggable Transceivers

To install a transceiver in a Summit X450-G2 Series switch:
1

Attach the anti-static wrist strap. Refer to the instructions on the 
anti-static wrist strap package.

2 Carefully align the transceiver with the port slot and push the 

transceiver into the port slot until the transceiver clicks and locks 
into place.

Installing the Fan Tray

To install the front-to-back fan tray in a Summit X450-G2 Series switch:
1

Carefully slide the fan tray module into the switch (see 

Figure 2

callout 8).

2 Align and fully tighten the captive retaining screws with a 1/4-inch 

flat-blade screwdriver.

Caution: 

Before rack-mounting the device, ensure that the rack can 

support it without compromising stability. Otherwise, personal 
injury and/or equipment damage may result.

Note: 

The rack mounting brackets provide two holes for securing 

the Summit X450-G2 Series switch to the rack. Use two screws or 
fasteners appropriate to your rack on each side when securing the 
X450-G2 Series switch to the rack.
We recommend that you install the power supplies in the Summit 
X450-G2 Series switch after you have secured the switch to the rack 
to minimize weight that must be supported when installing rack 
screws.

Note: 

If using one power supply, you can install it in either of the two 

power supply bays. Insert a blank cover, provided with the switch, on 
the unused power supply bay.

Warning: 

Fiber-optic SFP and SFP+ ports use Class 1 or Class 1M 

lasers. 
LASER RADIATION
DO NOT EXPOSE USERS OF TELESCOPIC OPTICS
CLASS 1 OR 1M LASER PRODUCT
Do not use optical instruments to view the laser output. The use of 
optical instruments to view laser output increases eye hazard.
Use only UL/CSA recognized pluggable modules.

Avertissements: 

Les ports de fibre optique SFP et SFP+ utilisent 

un faisceau laser de classe 1 ou M1. 
RAYONNEMENT LASER
NE PAS EXPOSER LES UTILISATEURS D’INSTRUMENTS 
OPTIQUES TÉLESCOPIQUES
PRODUIT LASER DE CLASSE 1 OU M1
N'utilisez pas d'instrument optique pour visualiser la sortie du 
faisceau laser. L'utilisation d'un instrument optique pour l'observer 
accroît le risque de lésions oculaires.
Utilisez uniquement des modules enfichables homologués par l’UL/
CSA

Caution: 

You must install the front-to-back fan tray (Part # 10945) 

before connecting power to the switch. 

Note: 

The X450-G2 Series switch does not ship with the fan tray. 

You must purchase the front-to-back fan tray separately.

Connecting Power to the Switch

PoE+ Switches

After you have installed the power supply modules, you can connect to 
a single, primary source of power, or to two sources of power for 
redundancy. 
To power-up your X450-G2 Series switch:
1

Attach the power cord from your redundant power supply into the 
X450-G2 Series switch’s power supply receptacle. 

2 Once power is connected, verify that the PSU LED (P1 and/or P2) 

turns green. If the PSU LED does not turn green, refer to the 

Extreme 

Networks Summit Family Hardware Installation Guide

 for 

troubleshooting information.

Non-PoE Switches

You can connect to a single, primary source of power, or to two sources 
of power for redundancy. The example used here describes connecting 
to two power sources.
To power-up your X450-G2 Series switch:
1

Attach the power cord from your redundant power supply into the 
X450-G2 Series switch’s redundant power receptacle.

2 Attach the AC power cord to the X450-G2 Series switch’s AC power 

receptacle.

3 Plug the redundant power supply and the X450-G2 Series switch AC 

power cords into dedicated, grounded AC outlets.

4 Once power is connected, verify that the CPU (system) LED turns 

amber until the X450-G2 Series switch finishes its initialization.

If the initialization process is successful, the CPU LED turns green. If the 
CPU LED does not turn green, refer to the 

Extreme Networks Summit 

Family Hardware Installation Guide

 for troubleshooting information. 

Purchasing Power Cords

The X450-G2 switches do not include AC power input cords. To 
purchase the correct power cord for your location, refer to 

www.extremenetworks.com/product/powercords/

.

Initial Network Connection and Configuration

Once you have connected power to the switch and verified LED 
activity, complete the setup process as follows:
1

Connect a management station to the console port using either an 
Ethernet to serial adapter or DB-9 serial cable. 

2 Verify that the system LEDs are on (solid green or blinking green).
3 Using PuTTY, TeraTerm, or other terminal emulator, connect to the 

switch using the serial port connection. Be sure that your serial 
connection is set properly:

9600 baud

8 data bits

1 stop bit

4 Using the console session, perform the following:

a At the password prompt, press 

ENTER

 twice. 

b Enter user: 

admin

c For the initial password, simply press 

ENTER

.

d Follow the screen prompts for initial configuration.
e Enter  the 

show version 

command. Record the switch serial 

number. The following is example output with the serial 
number in bold: 

Transit.3 # show version
Switch : 800444-00-05 

1208G-00882

 Rev 5.0 BootROM

5 Go to Extreme Networks eSupport at

 https://

esupport.extremenetworks.com

6 After logging in, go to the product registration page: 

http://

extrwebapps.extremenetworks.com/Webapps/Public/ProductReg/.

7 Enter the serial number of the switch.
8 Download the software to your PC from the software download 

page at the eSupport website: 

https://

esupport.extremenetworks.com/eservice_enu/
start.swe?SWECmd=Login&SWEPL=1&SWETS=

9 Connect back to the switch via the console port and connect an 

Ethernet cable from the switch’s management port to your PC.

10 If necessary, reset the IP address on your PC (for example, 

10.10.10.10 255.255.255.0)

 to avoid IP conflict. 

11 At the switch, set the IP address of the switch (for example, enter: 

con mgmt ipa 10.10.10.9/24

). 

12 Enter 

save config

 to save your configuration.

Warning: 

Extreme Networks power supplies do not have switches 

for turning the unit on and off. Disconnect all power cords to remove 
power from the device. Make sure that these connections are easily 
accessible.

Avertissements: 

Les sources d’alimentation d’Extreme Networks ne 

sont pas munies d’interrupteurs pour éteindre ou mettre l’appareil 
sous tension. Débranchez tous les cordons d’alimentation pour 
couper le courant à l’appareil. Assurez-vous que ces connexions 
sont facilement accessibles.

Warning: 

A dedicated Listed circuit breaker rated at 15A is to be 

used for each power supply connection.

Avertissements: 

Utilisez un disjoncteur coté et dédié de 15 A pour 

chacune des connexions d’alimentation électrique.

Note: 

The PoE+ Summit X450-G2 Series switches do not ship with 

any power supplies. You must purchase the front-to-back power 
supplies (715W or 1100W) separately. See 

Table 2

.

Note: 

We strongly recommend that you change your password. 

13 Start a TFTP session using a program such as TFTPD64. Point the 

TFTP server to your PC IP address and EXOS image file saved on 
you PC. 

14 At the switch, download the new software to the switch. (example:

 

download image 10.10.10.10 summitX-15.4.1.3-patch1-
9.xos

).

15 Install the software after it loads by typing 

Y

 when prompted if you 

want to install the load.

16 When the download and install finishes, instruct the switch to reboot 

when prompted by entering: 

reboot

Optional CLI Commands

Once logged into the switch you can create new VLANs by issuing the 
following two commands:

create vlan <vlan name>

configure vlan <vlan name> tag XXXX 

Replace XXXX with the VLAN tag number (1–4096)

These two commands will create a VLAN, give it a logical name, and 
assign a tag number. 
To configure a Default Gateway in the Extreme Networks CLI enter: 

configure iproute add default <IP address>

 

Port Configuration CLI Commands

For additional port configuration CLI commands, refer to the 

ExtremeXOS Command Reference Guide

 at: 

www.extremenetworks.com/documentation.

Specifications

Temperature and Humidity

Operating: 0°C to 50°C (32°F to 122°F)
Storage: -40°C to 70°C (-40°F to 158°F)
Operating relative humidity: 10% to 95% (non-condensing)

Switch Dimensions

4.40 cm (1.73”) Height x 44.1 cm (17.4”) Width x 48.7 cm (19.2”) Depth 

Interfaces

Each X450-G2 Series switch has a USB, console, and management port. 
The following table lists the specific data interfaces for each model. 

Power Supplies

Table 1

X450-G2 Series Interface Descriptions

X450-G2-24t-GE4 
(Part # 16172)

24 10/100/1000BASE-T, 4 1000BASE-X 
unpopulated SFP, two 21Gb stacking ports (QSFP+)

X450-G2-24t-10GE4
(Part # 16176)

24 10/100/1000BASE-T, 4 10GBASE-X unpopulated 
SFP+, two 21Gb stacking ports (QSFP+) 

X450-G2-48t-GE4
(Part # 16174)

48 10/100/1000BASE-T, 4 1000BASE-X 
unpopulated SFP, two 21Gb stacking ports (QSFP+)

X450-G2-48t-10GE4
(Part # 16178)

48 10/100/1000BASE-T, 4 10GBASE-X unpopulated 
SFP+, two 21Gb stacking ports (QSFP+)

X450-G2-24p-GE4
(Part # 16173)

24 10/100/1000BASE-T POE+, 4 1000BASE-X 
unpopulated SFP, two 21Gb stacking ports (QSFP+)

X450-G2-24p-10GE4
(Part # 16177)

24 10/100/1000BASE-T POE+, 4 10GBASE-X 
unpopulated SFP+, two 21Gb stacking ports 
(QSFP+)

X450-G2-48p-GE4
(Part # 16175)

48 10/100/1000BASE-T POE+, 4 1000BASE-X 
unpopulated SFP, two 21Gb stacking ports (QSFP+)

X450-G2-48p-10GE4
(Part # 16179)

48 10/100/1000BASE-T POE+, 4 10GBASE-X 
unpopulated SFP+, two 21Gb stacking ports 
(QSFP+)

Table 2

X450-G2 Series Power Supply Specifications

X450-G2 Series Model

Power Supply 

Fixed power supply with front-to-back airflow

X450-G2-24t-GE4 (Part # 16172)
X450-G2-24t-10GE4 (Part # 16176)

100-240V~, 50/60 Hz, 1.0 A

X450-G2-48t-GE4 (Part # 16174)
X450-G2-46t-10GE4 (Part # 16178)

100-240V~, 50/60 Hz, 1.0 A

Modular power supply with front-to-back airflow

X450-G2-24p-GE4 (Part # 16173)
X450-G2-24p-10GE4 (Part # 16177)

1100W AC PS FB (front to back)
Part #: 10941, Model: PSSF112101A  
100-127V/200-240V~, 50-60 Hz, 
10.0 A/5.0 A max per PS

715W AC PS FB (front to back) 
Part #: 10951, Model: PSSF711101A
100-127V/200-240V~, 50-60 Hz, 
7.0 A/3.5 A max per PS

X450-G2-48p-GE4 (Part # 16175)
X450-G2-48p-10GE4 (Part # 16179)

1100W AC PS FB (front to back)
Part #: 10941, Model: PSSF112101A  
100-127V/200-240V~, 50-60 Hz, 
12.0 A/6.0 A max per PS

715W AC PS FB (front to back) 
Part #: 10951, Model: PSSF711101A
100-127V/200-240V~, 50-60 Hz, 
8.0 A/4.0 A max per PS

Отзывы: