User Manual of TI10 Series Variable Frequency Drive
- 40 -
Parameter
Name
Setting range
Factory value
Register
address
Properties
Hundreds: simple PLC
power-down memory
0: power-down reset
1: power-down storage
Thousands: simple PLC
time unit
0: second (s)
1: minute (min)
P42.01
Setting of PLC
stage 1
Ones: operation
direction of simple PLC
stage
0: positive
1: negative
Tens: acceleration and
deceleration time of
simple PLC stage
0: acceleration and
deceleration time 1
1: acceleration and
deceleration time 2
2: acceleration and
deceleration time 3
3: acceleration and
deceleration time 4
00
0x4201
●
P42.02
Running time
in stage 1
0.0s(min)~3276.7s(min)
0.0s(min)
0x4202
○
P42.03
Setting of PLC
stage 2
refers to the setting
mode of stage 1
00
0x4203
●
P42.04
Running time
in stage 2
0.0s(min)~3276.7s(min)
0.0s(min)
0x4204
○
P42.05
Setting of PLC
stage 3
refers to the setting
mode of stage 1
00
0x4205
●
P42.06
Running time
in stage 3
0.0s(min)~3276.7s(min)
0.0s(min)
0x4206
○