User Manual of TI10 Series Variable Frequency Drive
- 8 -
Parameter
Name
Setting range
Factory value
Register
address
Properties
result switching of
frequency
Tens: given operation
relation of frequency
main and auxiliary
0: Min[main, auxiliary]
1: Max[main, auxiliary]
2: Sub[main, auxiliary]
3: Add[main, auxiliary]
P00.07
Maximum
frequency
10.00Hz~300.00Hz
50.00Hz
0x0007
●
P00.08
upper limit
frequency
Lower limit
frequency~maximum
frequency
50.00Hz
0x0008
●
P00.09
Lower limit
frequency
0.00Hz~upper limit
frequency
0.00Hz
0x0009
●
P00.10
Jumping
frequency 1
0.00Hz~upper limit
0.00Hz
0x000A
●
P00.11
Jumping range
1
0.00Hz~30.00Hz
0.00Hz
0x000B
●
P00.12
Jumping
frequency 2
0.00Hz~upper limit
0.00Hz
0x000C
●
P00.13
Jumping range
2
0.00Hz~30.00Hz
0.00Hz
0x000D
●
P00.14
Jumping
frequency 3
0.00Hz~upper limit
0.00Hz
0x000E
●
P00.15
Jumping range
3
0.00Hz~30.00Hz
0.00Hz
0x000F
●
P00.16
Jog frequency
setting
0.00Hz~upper limit
5.00Hz
0x0010
●
P01 start-stop control parameters
Содержание TI10 Series
Страница 1: ...THINK DRIVES THE WORLD TI10SeriesVFD UserManual...