User Manual of TI10 Series Variable Frequency Drive
- 17 -
Parameter
Name
Setting range
Factory value
Register
address
Properties
+AI1
P04.14
V/F separation
mode voltage
digital given
0.0%~100.0%
0.0%
0x040E
○
P04.15
V/F separation
mode voltage
change time
0.00s~600.00s
0.01s
0x040F
○
P10 switching value x input
P10.00
X1 terminal
function
selection
00: no function
01: forward running
(FWD)
02: reverse running
(REV)
03: forward running
inching (FJOG)
04: reverse inching
(RJOG)
05: 3-wire operation
06: free stop
07: emergency stop
08: external stop
09: operation forbidden
10: operation
suspended
11: external fault input
12: fault reset (RESET)
13: terminal adjustment
Up
14: terminal adjustment
Down
15: Up/Down setting
clearing (terminal,
1
0x1000
●
P10.01
X2 terminal
function
selection
2
0x1001
●
P10.02
X3 terminal
function
selection
16
0x1002
●
P10.03
X4 terminal
function
17
0x1003
●
Содержание TI10 Series