User Manual of TI10 Series Variable Frequency Drive
- 12 -
Parameter
Name
Setting range
Factory value
Register
address
Properties
P03.00
Speed/torque
control
selection
Ones: Vector control
selection
0: speed control
1: torque control
Tens: power generation
limit
0: invalid
1: whole process
2: constant speed
3: slow down
00
0x0300
●
P03.01
Speed loop
high speed
proportional
gain
0.00~30.00
2.00
0x0301
○
P03.02
Speed loop
high speed
integration
time
0.001~5.000s
0.200s
0x0302
○
P03.03
Speed loop
low speed
proportional
gain
0.00~30.00
2.00
0x0303
○
P03.04
Speed loop
low speed
integration
time
0.001~5.000s
0.200s
0x0304
○
P03.05
Speed loop PI
switching
frequency 1
0.00Hz~P03.06
5.00Hz
0x0305
○
P03.06
Speed loop PI
switching
frequency 2
P03.05~upper limit
frequency
10.00Hz
0x0306
○
P03.07
Speed
feedback
filtering time
0.0ms~1000.0ms
15.0ms
0x0307
○
P03.08
Drive torque
Ones: torque control
90
0x0308
●