User Manual of TI10 Series Variable Frequency Drive
- 14 -
Parameter
Name
Setting range
Factory value
Register
address
Properties
P03.12
Limiting
channel of
torque control
frequency
Ones: frequency
forward limit channel
Tens: frequency reverse
limit channel
0: digital setting P03.13/
P03.14
1: analog input AI1
2: analog input AI2
3: reserve
4: Min[AI1,AI2]
5: Max[AI1,AI2]
6: Sub[AI1,AI2]
7: Add[AI1,AI2]
8: pulse given HDI
00
0x030C
●
P03.13
Positive setting
of torque
control
frequency
0.00Hz~maximum
frequency
50.00Hz
0x030D
○
P03.14
Reverse
setting of
torque control
frequency
0.00Hz~maximum
frequency
50.00Hz
0x030E
○
P03.15
Limiting bias of
torque control
frequency
0.00Hz~maximum
frequency
0.00Hz
0x030F
○
P03.16
Adjustment
proportional
gain of
excitation
current
0~60000
2000
0x0310
○
P03.17
Adjustment
integral gain of
excitation
current
0~60000
1000
0x0311
○
P03.18
Adjustment
proportional
gain of torque
0~60000
2000
0x0312
○