User Manual of TI10 Series Variable Frequency Drive
- 37 -
Parameter
Name
Setting range
Factory value
Register
address
Properties
P40.29
Upper critical
value of zero
frequency
operation
P40.30~upper limit
frequency
0.00Hz
0x401D
●
P40.30
Lower critical
value of zero
frequency
operation
0.00Hz~P40.29
0.00Hz
0x401E
●
P40.31
Sleep wake-up
mode selection
0: Frequency sleep
wake-up mode
Sleep wake-up mode is
determined by P40.29 and
P40.30 parameter settings
1: Pressure sleep
wake-up method
Sleep wake-up mode is
determined by P40.32 and
P40.34 parameter settings
0
0x401F
●
P40.32
Sleep pressure
detection value
P40.34
~
P40.37
1000
0x4020
●
P40.33
Sleep detection
delay time
0.00s
~
30.00s
Effective for frequency
and pressure detection
methods
1.00s
0x4021
●
P40.34
Wakeup
pressure
detection value
0
~
P40.32
0
0x4022
●
P40.35
Wakeup
detection delay
time
0.00s
~
30.00s
Effective for frequency
and pressure detection
methods
0.50s
0x4023
●
P40.36
reserve