User Manual of TI10 Series Variable Frequency Drive
- 39 -
Parameter
Name
Setting range
Factory value
Register
address
Properties
P41.11
Multistage
frequency
digital given 12
Lower limit
frequency~upper limit
frequency
0.00Hz
0x410B
○
P41.12
Multistage
frequency
digital given 13
Lower limit
frequency~upper limit
frequency
0.00Hz
0x410C
○
P41.13
Multistage
frequency
digital given 14
Lower limit
frequency~upper limit
frequency
0.00Hz
0x410D
○
P41.14
Multistage
frequency
digital given 15
Lower limit
frequency~upper limit
frequency
0.00Hz
0x410E
○
P41.15
Multistage
frequency 1
command
source
selection
0: digital given P41.00
1: analog input AI1
2: analog input AI2
3: reserve
4: Min[AI1,AI2]
5: Max[AI1,AI2]
6: Sub[AI1,AI2]
7: Add[AI1,AI2]
8: pulse given HDI
9: process PID
0
0x410F
●
P42 Simple PLC
P42.00
Selection of
simple PLC
operation
mode
Ones: simple PLC
operation mode
0: shutdown after single
cycle
1: maintain final value
after single cycle
2: continuous cycle
Tens: simple PLC
startup mode
0: run from stage 1
1: continue to operate
from the stage
frequency at the
interruption time
0000
0x4200
●