User Manual of TI10 Series Variable Frequency Drive
- 6 -
Chapter 2 Parameter List
Parameter symbol description:
○: Indicate that the parameter can be modified during running
●: Indicate that the parameters cannot be modified during running and can be modified
during shutdown.
★
: Indicate that the parameters are read-only, such as monitoring parameters
☆
: Indicate that the function is supported on the expansion card
Parameter
Name
Setting range
Factory value
Register
address
Properties
P00 frequency given parameters
P00.00
Digital setting
of main
frequency
0.00Hz~upper limit
frequency
50.00Hz
0x0000
○
P00.01
Main
frequency
source
selection
0:digital given
(P00.00)+Up/Down
adjustment
1: analog input AI1
2: analog input AI2
3:reserve
4:Min[AI1,AI2]
5:Max[AI1,AI2]
6:Sub[AI1,AI2]
7:Add[AI1,AI2]
8: pulse given HDI
9: process PID
A: simple PLC
B:External keyboard
potentiometer
C:no given
3
0x0001
○
P00.02
Digital setting
of auxiliary
frequency
0.00Hz~upper limit
frequency
50.00Hz
0x0002
○
Содержание TI10 Series