TI120 Series Variable Frequency Drive
Detailed parameter introduction
- 127 -
reaching" terminal outputs a valid signal; and acts according to the mode set by the P43.02 ones.
P43.04
Number of pulses per meter
range:0.1~6553.5
Factory
default:1000.0
Set the pulse number per meter length to calculate the length value.
P43.05
Linear speed display
coefficient
range:0.0%~1000.0%
Factory default:0.0%
P44 Lifting function parameters (only for crane models)
P44.00
Crane device selection
range:0x00~0x12
Factory default:00
ones: device selection
0: forbidden
1: vertical movement device
When the variable frequency drive is used in the lifting mechanism, please keep the variable
frequency drive up when it is rotating forwards and downward when it is reverse. If the actual direction is
different from the required direction, please replace any two-phase wiring of the three-phase output of
the variable frequency drive. Selecting the lifting mechanism is switched to the terminal control
automatically, and the brake output is opened at the same time.
2: horizontal movement device
It is used for horizontal movement mechanism of trolley.
Tens: reserve
P44.01
Upward brake opening
frequency
range:0.00Hz~10.00Hz
Factory
default:2.00Hz
P44.02
Upward brake opening current
range:0.0%~200.0%
Factory
default:30.0%
It is used for judging the value of the frequency and current of the brake release when lifting up.
When the variable frequency drive is running forwards and the output frequency and current reach the
setting value, the brake release time is counted; after the timer is reached, the brake release is in
accelerated running.
P44.03
Downward brake opening
frequency
range:0.00Hz~10.00Hz
Factory
default:3.00Hz
P44.04
Downward brake opening
current
range:0.0%~200.0%
Factory
default:30.0%
It is used for judging the value of the frequency and current of the brake release when lifting down.
When the variable frequency drive is running reversely and declines, and the output frequency and
current reach the setting value, the brake release time is counted; after the timer is reached, the brake
release is in accelerated running.
P44.05
Holding time of brake opening
current
range:0.0s~10.0s