TI120 Series Variable Frequency Drive
Detailed parameter introduction
- 125 -
The stage before the memory is powered off, and it starts from the stage of the memory when the
power is on again.
Thousands: simple PLC time unit
0: second (s)
1: minute (min)
Set the unit of PLC stage running time.
P42.01
Setting of PLC stage 1
range:0x00~0x13
Factory default:00
Ones: operation direction of simple PLC stage
0: positive
1: negative
Define the running direction of PLC stage 1.
Tens: acceleration and deceleration time of simple PLC stage
0: acceleration and deceleration time 1
1: acceleration and deceleration time 2
2: acceleration and deceleration time 3
3: acceleration and deceleration time 4
Select the acceleration and deceleration time of PLC stage 1.
P42.02
Running time in stage 1
range:0.0~3276.7
Factory default:0.0
Set the running time of stage1, the time unit is determined by the thousands of function code
P42.00. The run frequency of PLC stage 1 is set by P41.00 function code, and the run frequency of PLC
stage 2 is set by P41.01 function code; in turn, the run frequency of PLC stage 15 is set by function code
P41.14.
P42.03
Setting of PLC stage 2
range:0x00~0x13
Factory default:00
P42.04
Running time in stage 2
range:0.0~3276.7
Factory default:0.0
P42.05
Setting of PLC stage 3
range:0x00~0x13
Factory default:00
P42.06
Running time in stage 3
range:0.0~3276.7
Factory default:0.0
P42.07
Setting of PLC stage 4
range:0x00~0x13
Factory default:00
P42.08
Running time in stage 4
range:0.0~3276.7
Factory default:0.0
P42.09
Setting of PLC stage 5
range:0x00~0x13
Factory default:00
P42.10
Running time in stage 5
range:0.0~3276.7
Factory default:0.0
P42.11
Setting of PLC stage 6
range:0x00~0x13
Factory default:00
P42.12
Running time in stage 6
range:0.0~3276.7
Factory default:0.0
P42.13
Setting of PLC stage 7
range:0x00~0x13
Factory default:00
P42.14
Running time in stage 7
range:0.0~3276.7
Factory default:0.0
P42.15
Setting of PLC stage 8
range:0x00~0x13
Factory default:00
P42.16
Running time in stage 8
range:0.0~3276.7
Factory default:0.0
P42.17
Setting of PLC stage 9
range:0x00~0x13
Factory default:00