TI120 Series Variable Frequency Drive
Specification and Model Selection
- 146 -
Program
Technical specification
Starting torque
SVC:0.25Hz 150%
VC: 0.00Hz 180%
Speed regulation
range
SVC: 1:200
VC: 1:1000
Speed
stabilization
precision
SVC: ±0.5%
VC: ±0.2%
Torque control
precision
SVC: above 5Hz±5%
VC: above 5Hz±3%
Torque reentry
precision
≤0.5% rated torque of motor
Torque response
time
SVC: ≤ 10ms (rated torque of motor)
VC: ≤ 5ms (rated torque of
motor)
Torque boost
Automatic torque lifting function; manual torque increases by
0.1%~30.0%
V/F curve
Straight line, multiple power curve, multiple point curve, V/F separation
Acceleration and
deceleration curve
Straight line, broken line, S curve
Direct current
brake
Starting frequency of DC brake :0.00~300.00Hz
;
DC braking current:
constant torque 0.0~120.0%
;
variable torque 0. 0~90.0%
Direct current brake time: 0.0~30.0s
;
realize quick brake without direct
current brake initial waiting time
Inching control
Inching frequency range:0.00Hz~50.00Hz
Inching acceleration and deceleration time range:0.0s~3600.0s
Process closed
loop PID
The process closed loop control system can be conveniently realized
Simple PLC,
multi-stage
instruction
At most 16 speed stages can be easily realized through built-in simple
PLC or X terminal.
Automatic voltage
regulation
When the power grid voltage fluctuates, the output voltage can be
automatically kept stable.
Overflow,
over-voltage and
stall control
The current and voltage during operation are automatically limited to
prevent frequent over-current and over-voltage tripping.
Automatic fast
current limiting
Minimize over-current faults and protect the normal operation of the
drive.
Torque limit and
control
"Excavator" feature automatically limits torque during operation to
prevent frequent over-current tripping; in vector control, torque control