Keypad Display Menu Tree of DensityPRO Gauges
Thermo Scientific
DensityPRO User Manual
A-15
MAIN
MENU
COMMANDS
PHYSICAL
I/O
DETECTOR
PREV…
PHYSICAL
I/O
CURRENT/Vdc
INPUT
DIGITAL
INPUT
CURRENT
OUTPUT
MORE…
CURRENT
OUTPUT
CURRENT
OUTPUT
#A
CURRENT
OUTPUT
#B
CURRENT
OUTPUT
#C
CURRENT
OUTPUT
#A
MEASUREMENT
SOURCE
MODE
AND
HOLD
RANGE
SETTINGS
ALARM
ACTION
CALIBRATE
DIAGNOSTICS
MEASUREMENT
SOURCE
INPUT
ID
B
NONE
MEASUREMENT
ID
B
NONE
MEASUREMENT
SOURCE
OUTPUT
TYPE
B
NONE
SOURCE
UNIT
(EU)
B
NONE
BACK
EDIT
NEXT
BACK
NEXT
BACK
NEXT
BACK
EDIT
NEXT
BACK
EDIT
NEXT
CURRENT
OUTPUT
#A
MEASUREMENT
SOURCE
MODE
AND
HOLD
RANGE
SETTINGS
ALARM
ACTION
CALIBRATE
DIAGNOSTICS
MODE
AND
HOLD
MODE
B
NORMAL
HOLD/LIVE
B
LIVE
HOLD
VALUE
(EU)
B
0.000000
BACK
NEXT
BACK
EDIT
CURRENT
OUTPUT
#A
MEASUREMENT
SOURCE
MODE
AND
HOLD
RANGE
SETTINGS
ALARM
ACTION
CALIBRATE
DIAGNOSTICS
RANGE
SETTINGS
MIN
mA:
4.000000
MAX
mA:
20.00000
Min
Value@Min
mA
B
0.000000
Max
Value@Max
mA
B
100.0000
BACK
NEXT
BACK
EDIT
CURRENT
OUTPUT
#A
MEASUREMENT
SOURCE
MODE
AND
HOLD
RANGE
SETTINGS
ALARM
ACTION
CALIBRATE
DIAGNOSTICS
ALARM
ACTION
ALARM
ACTION
B
NONE
BACK
NEXT
BACK
EDIT
CURRENT
OUTPUT
#A
MEASUREMENT
SOURCE
MODE
AND
HOLD
RANGE
SETTINGS
ALARM
ACTION
CALIBRATE
DIAGNOSTICS
CALIBRATION
MENUS
mA
CALIBRATION
RAW
CALIBRATION
BEGIN
CALIBRATION
mA
CALIBRATION
#1
mA
Min
VALUE
B
4.000000
#2
mA
Mid
VALUE
B
12.00000
#3
mA
Max
VALUE
B
20.00000
BACK
NEXT
BACK
NEXT
BACK
EDIT
CALIBRATION
MENUS
mA
CALIBRATION
RAW
CALIBRATION
BEGIN
CALIBRATION
RAW
CALIBRATION
#1
RAW
Min
VALUE
B
4.000000
#2
RAW
Mid
VALUE
B
12.00000
#3
RAW
Max
VALUE
B
20.00000
BACK
NEXT
BACK
EDIT
CALIBRATION
MENUS
mA
CALIBRATION
RAW
CALIBRATION
BEGIN
CALIBRATION
BEGIN
CALIBRATON
ENTER
CAL
POINT:
3PointCa
OR
PRESS
NEXT
TO
START
CALIBRATION
BACK
NEXT
BACK
EDIT
NEXT
PASSWORD
VALIDATION
USER
PASSWORD
ENTRY
B
0
DISPLAY
PASSWORD
MODE
B
DISPLAY
INVALID
PASSWORD
B
COUNT:
0
PASSWORD
VALIDATION
ENGINEER
MODE
COUNT
B
7
TECHNICIAL
MODE
COUNT
B
0
OPERATOR
MODE
COUNT
B
0
PASSWORD
VALIDATION
COM
A
PASSWORD
MODE
B
DISPLAY
COM
B
PASSWORD
MODE
B
DISPLAY
Ethernet
Password
Mode
B
DISPLAY
PASSWORD
VALIDATION
USB
PASSWORD
MODE
B
DISPLAY
SMART
PASSWORD
MODE
B
DISPLAY
CURRENT
PASSWORD
MODE
B
DISPLAY
BACK
EDIT
NEXT
BACK
EDIT
NEXT
BACK
EDIT
NEXT
BACK
EDIT
NEXT
CURRENT
OUTPUT
#A
MEASUREMENT
SOURCE
MODE
AND
HOLD
RANGE
SETTINGS
ALARM
ACTION
CALIBRATE
DIAGNOSTICS
DIAGNOSTICS
STATUS:
B
LIVE
LIVE
VALUE
(EU)
B
0.000000
PRESENT
VALUE
B
4.0000
BACK
NEXT
BACK
EDIT
Figure
A-15.
Physical I/O, Current Output
Содержание DensityPRO NAI Series
Страница 2: ......
Страница 4: ......
Страница 6: ...This page intentionally left blank ...
Страница 8: ...This page intentionally left blank ...
Страница 14: ...xiv DensityPRO User Manual Thermo Scientific This page intentionally left blank ...
Страница 22: ...A xxii DensityPRO User Manual Thermo Scientific Quick Setup This page intentionally left blank ...
Страница 124: ...Operation Application Screens 4 72 DensityPRO User Manual Thermo Scientific Figure 4 39 High and Low Alarms ...
Страница 134: ......
Страница 158: ......
Страница 195: ......