Operation
Application Screens
4
-
56
DensityPRO User Manual
Thermo Scientific
n.
The Carrier Volume Flow measurement is derived from the primary density
value, Carrier Density constant, Solid Density constant and in conjunction
with the flow measurement selected from the Input Configuration tab.
o.
The Bulk Solids Flow measurement is derived from the primary density value,
Carrier Density value, Solid Density value, Bulk Solid Density constant and in
conjunction with the flow measurement selected from the Input
Configuration tab.
p.
The Temperature measurement is derived from the analog input selection
made in Input Configuration.
q.
The Velocity measurement value is derived based on the flow selection made
under Input Configuration and based on the pipe inside diameter. The
measurement will be automatically converted to the user-selected unit, either
ft/sec or m/sec.
r.
The Proppant measurement is derived from the primary density value, the
primary density constant carrier density value and the solid density value.
3.
Each measurement unit will auto-populate based on the measurement type
selected.
4.
Use the fields under Number of Decimal Places to determine the number of
decimal places to display. These fields are configurable from 0 to 4.
5.
In each instance where the Density, Temperature, Pressure or Flow Inputs are set
to Not Used, then Measurement #1 will be used on the Measurement Data tab.
Содержание DensityPRO NAI Series
Страница 2: ......
Страница 4: ......
Страница 6: ...This page intentionally left blank ...
Страница 8: ...This page intentionally left blank ...
Страница 14: ...xiv DensityPRO User Manual Thermo Scientific This page intentionally left blank ...
Страница 22: ...A xxii DensityPRO User Manual Thermo Scientific Quick Setup This page intentionally left blank ...
Страница 124: ...Operation Application Screens 4 72 DensityPRO User Manual Thermo Scientific Figure 4 39 High and Low Alarms ...
Страница 134: ......
Страница 158: ......
Страница 195: ......