Main Menu
81
Options
Figure 66: Options
This Menu is used to:
1. Turn ON/OFF a Module/Feature.
2. Select a particular Option within a module.
3. Tell the Controller when a Sensor is mounted.
Here is the list of Modules, Features and Options under this menu (See Setpoint/Controlling section
previously in this chapter for more details on each option):
AFAM Module:
Select from None, AVL, AFAM, and AFAM+. Selecting AFAM+ also turns Optiset ON.
Humidity Sensor:
Select from None, Sensor Mounted and Sensor Mounted (RS-485)
Suction Pressure Sensor:
Select from None or Sensor Mounted.
Discharge Pressure Sensor :
Select from None or Sensor Mounted.
AVL Sensor :
Select from None or Sensor Mounted.
MTS Feature:
Select ON/OFF.
CT Feature:
Select ON/OFF.
Smart PYI Trial:
Select ON/OFF.