NOTE: See detailed Alarm/Warning Code list complete with corrective actions in the Diagnosing and
Troubleshooting Section in the back of the manual.
Warning List Menu
Warning Code Action
1
High Pressure Cut Out, Check Water Cooling
6
High Pressure Cut Out, Check Condenser Probe
8
High Pressure Cut Out, Please Wait
13
Evaporator High Temperature - Check Heater System
20
Low Voltage On Line - Unit Stopped
21
Current Too High - Check Compressor and Fans
22
Current Too Low - Check Compressor and Fans
23
Supply Temperature Too High - Check Sensors
24
Supply Temperature Too Low - Check Evaporator Coil
25
Evaporator Temperature Too High - Check Evaporator Sensor
26
Evaporator Temperature Too Low - Check Evaporator Sensor
27
System Low Pressure - Check Refrigerant Charge
28
Frozen Setpoint - Check Air Exchange
30
High Pressure Cut Out - Please Wait
31
HPCO (High Pressure Cut Out) Timer Hold - Please Wait
32
Low Pressure Cut Out - Please Wait
33
LPCO (Low Pressure Cut Out) Timer Hold - Please Wait
34
Compressor Too High Temperature Timer - Please Wait
35
Compressor High Temperature
36
AVL Open - Check FAE and CA Settings
37
CO2 Reading Stuck for >24 Hours
38
High Voltage On Line
39
Battery Charger/Heater - Check Battery
40
12V Sensor PSU Problem
41
Power Module Heat Exchanger High Temperature – Please Wait
42
CA Unit LPCO
43
CA Unit HPCO
44
CA Unit OBS
45
45 Wall Clock Failure
46
Battery Needs Charging
Содержание 098203
Страница 2: ......
Страница 3: ...MAGNUM TK 60275 4 MM Rev 3 08 15 Copyright 2012 Ingersoll Rand EMEIA Printed in Ireland...
Страница 193: ...Refrigeration Maintenance 191 Figure 163 Filter Drier...
Страница 200: ...Refrigeration Maintenance 198 Figure 169 Receiver Tank Figure 170 Water Cooled Condenser Tank...
Страница 257: ...255 Schematic Diagram RELEASED 19 Sep 2013...
Страница 258: ...256 Wiring Diagram Page 1 of 2 RELEASED 19 Sep 2013...
Страница 259: ...257 Wiring Diagram Page 2 of 2 RELEASED 19 Sep 2013...
Страница 263: ......