Operating Instructions
60
4. Located J1 connector top left side of PM, disconnect J1 connector from PM. See Figure 28 on page
5. Plug unit in and turn CB ON. Observe the condenser fan rotation to be correct, air out of condenser
grille, CCW. If wrong turn CB OFF and unplug unit. Swap 2 of the CP wires and recheck for correct
fan rotation.
1.
J1 Connector Disconnect from PM
2.
CP Wires Connected to Output Side of Main CB
3.
CF Wires Connected at J11 and Input Side of Compressor Contactor
Figure 28: Rotation Check