Controller Description
48
Software Version 2.4.0.0 111220
Release Date
New Features
January 2012
MP4000 Test System Tool
Introduce field tester system tool (8232-010) functionality.
Alarm 127 GENERAL UNIT ERROR
Introduced Alarm 127 GENERAL UNIT ERROR shut down alarm. If controller is missing
needed information to run alarm will be set and unit will shut down. Possible errors could
be low voltage, no probe information (plug out), setpoint information or other vital
information to run. Correct error and acknowledge alarm.
Alarm 52 PROBE ERROR
Have reintroduce Alarm 52 PROBE ERROR. Sensor evaluation during the PTI test and/or
Probe Test. During the probe test if the test cannot determine which sensor is wrong,
alarm 52 PROBE ERROR will be set. SA, RT, EC sensor difference >1.5C
Alarm 120 SUCTION PRESSURE SENSOR ERROR
Alarm 31 LOW PRES CUTOUT
Alarms were being set on power ON and OFF. Power ON pressure reading based on
ambient were outside sensor range. Power OFF voltage deteriorating and sensor reading
inaccurate. Introduced transducer surveillance.
Evaporator Fan Speed Option
For prefixes NFLU and SONS with frozen setpoint, evaporator fans will run high speed
until -9.9C then switch to low speed fans
MTS Defaulted OFF on Power OFF
MTS setting would default OFF after a power OFF. Controller will retain setting until power
OFF period 5 days or pass PTI is passed.
COLD Treatment for HL
CT mode for HL will run in non optimized high or low speed evaporator fans all the time.
Humidity Controller
If humidity sensor is defective or removed, humidity controller is disabled.
AFAM+, AFAM Disable in Frozen Mode
AFAM functionality and CO2/O2 setting disabled in frozen mode.
AFAM Introduced
Introduced AFAM option and HL special features
AFAM door closes after ON/OFF key is press OFF
5 day period OFF, for HL remains ON
After pass PTI will default OFF
Setpoint to 10C only after pass PTI
RMM+ Controller Clock Update
Controller and server date and time must match. If they do not match the controller date
and time will be updated to the server GMT time and date.
RMM Built in Option
Added prefixes TEMU905600 through 908379 for RMM option.
RMM+ Graphics
Introduced graphics to show connection state for the RMM+ option. Icons will appear
above the RA temp in the main menu. Cell tower and satellite icon.
Software Version 2.4.2.0 120313
Release Date
New Features
April 2012
RMM Built in Option
Added prefixes TEMU911630 through 9912129 and ACLU596901 through 597000 for
RMM option.
Содержание 098203
Страница 2: ......
Страница 3: ...MAGNUM TK 60275 4 MM Rev 3 08 15 Copyright 2012 Ingersoll Rand EMEIA Printed in Ireland...
Страница 193: ...Refrigeration Maintenance 191 Figure 163 Filter Drier...
Страница 200: ...Refrigeration Maintenance 198 Figure 169 Receiver Tank Figure 170 Water Cooled Condenser Tank...
Страница 257: ...255 Schematic Diagram RELEASED 19 Sep 2013...
Страница 258: ...256 Wiring Diagram Page 1 of 2 RELEASED 19 Sep 2013...
Страница 259: ...257 Wiring Diagram Page 2 of 2 RELEASED 19 Sep 2013...
Страница 263: ......