Refrigeration Maintenance
199
Figure 171: Vapor Injection Valve
Vapor Injection Valve Replacement
NOTE: In most cases, only the coil requires replacement. No other repair is possible on solenoid
valves.
Valve Removal
To remove the vapor injection valve, perform the following steps:
1. Recover the refrigerant charge from the unit.
2. Turn the Unit On/Off switch Off. Disconnect electrical connections to valve coil.
3. Unsolder liquid line connections to the valve.
4. Remove the valve from the unit.
AJA2032